26
Service and Maintenance
MAINTENANCE
The Altrad Belle Pro Trowels are designed to give many years of trouble free operation. It is, however, important that the simple
regular maintenance listed in this section is carried out. It is recommended that an approved Altrad Belle dealer carries out all major
maintenance and repairs. Always use genuine Altrad Belle replacement parts, the use of spurious parts may void your warranty.
Before any maintenance is carried out on the machine, switch off the engine. If working on a petrol engined machine, disconnect the
HT lead from the sparkplug.
Running In Period
When the trowel is
¿
rst used from new, the engine oil must be changed after the initial running in period.
(see engine manual for full detail).
Note:
- Check the gearbox oil at regular intervals and top-up when necessary. Make sure the oil is at the centre of the sight glass. To
¿
nd
out what grade of oil should be used in the gearbox, please contact the Altrad Belle Warranty Department (+44 (0)1298 84606)
- Grease Spider Arm Assembly prior to storage and at regular intervals.
Oil/Fuel Type & Quantity - Spark Plug Type
Oil Type
Quantity
Fuel Typ
Capacity
Spark Plug
Electrode
Type
Gap
Gasoline GX160
SAE
0.16gal
Unleaded
0.66gal
BM4A or
0.6 - 0.7mm
Engine
10W-30
BMR4A
Gasoline EX17
SAE
0.3gal
Unleaded
0.95gal
NGK
0.6 - 0.7mm
Engine
10W-30
BR-6HS
Gasoline GX270
SAE
0.3gal
Unleaded
1.59gal
NGK
0.7 - 0.8mm
Engine
10W-30
BPR-6HS
Gasoline EX27
SAE
0.3gal
Unleaded
1.61gal
NGK
0.6 - 0.7mm
Engine
10W-30
BR-6HS
Gearbox
EP90
0.16gal
NA NA NA NA
Routine Maintenance
Daily after
¿
rst
¿
rst month
3 month
6 month
4 hours /
/ 20 h
/ 50 h
/ 100 h
Weekly
Engine Oil
Check Level
9
Change
9
9
Air Filter
Check Condition
9
9
Clean / Replace
9
Spark Plug
Check / Clean
9
Cutout Switch Check
9
Belt Tension
Check
9
Summary of Contents for PRO TROWEL 1200
Page 237: ...237 ...