Connect hose and regulator to cylinder.The propane gas and cylinder are sold separately.
Use a standard 20 lb. propane cylinder only.
Use this heater only with a propane vapor withdrawal supply system. See chapter 5 of the
standard for storage and handling of liquefied petroleum gas, ANS /NFPA 58. Your local
library or fire department should have this book.
A minimum supply pressure of 0.4 p.s.i. is required for the purpose of input adjustment for
propane gas. Storage of an appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance. A cylinder must be stored outdoors in a well-
ventilated area out of the reach of children. A disconnected cylinder must have dust caps
tightly installed and must not be stored in a building, garage or any other enclosed area.
The minimum permissible gas supply pressure of 10 W.C. is required for purpose of input
adjustment. The minimum hourly of 17000 Btu is required input rating for a heater for
automatic operation at ratings less than full input rating.
The pressure regulator and hose assembly supplied with the appliance must be used.
The installation must conform with local codes, or in the absence of local codes,with national
fuel gas code, ANS Z223.1/NFPA54, natural gas and propane Installation Code, CSA B149.1,
or propane storage and handling code, B149.2.