If
Try this
Nothing happens when I
press the smoke alarm test
button
Check that the battery contacts are firmly connected.
Replace the smoke alarm battery. Only use a Duracell
MN1604 alkaline battery.
Check the age of the unit, see the “replace by” label on
the sidewall of the unit.
The smoke alarm beeps
when I press the test button,
but the Visit receiver is not
responding
Check the smoke alarm battery and the receiver batteries
and connections.
Move the receiver closer to the smoke alarm to make sure
it’s within radio range.
Check that the units are set to the same radio key, see
Changing the radio key
.
The Visit receiver is activated
for no apparent reason
Change the smoke alarm battery if the red Visit LED on
the receiver blinks every 5 s, see
Signal pattern
.
If the problem persists, there is probably another Visit
system nearby that triggers yours. Change the radio key
on all units, see
Changing the radio key
.
The smoke alarm beeps
and chirps for no apparent
reason
Check for fumes, steam, etc. from the kitchen or bathroom.
Paint and other fumes can cause nuisance alarms.
Check for any sign of contamination such as cobwebs
or dust. If necessary, clean the alarm, see
Cleaning your
smoke alarm
.
If the problem persists, the smoke alarm is defective and
needs to be replaced.
Troubleshooting
Most problems with the smoke alarm can be solved quickly by following the advice below.
Service and support
If the product appears to be damaged or doesn’t function properly, follow the instruc-
tions in this user guide If the product still doesn’t function as intended, contact your
local dealer for information on service and warranty.
Warranty conditions
Bellman & Symfon guarantees this smoke alarm (excluding the battery) for two years from
date of purchase against any defects that are due to faulty materials or workmanship.
This guarantee only applies to normal conditions of use and service, and does not include
damage resulting from accident, neglect, misuse, unauthorized dismantling, or contamina-
tion howsoever caused. This guarantee excludes incidental and consequential damage. This
guarantee does not cover costs associated with the removal and/or installation of alarms.
If this smoke alarm should become defective within the guarantee period, it must be
returned to your local dealer, with proof of purchase, carefully packaged, and with the
problem clearly stated.
Do not interfere with the smoke alarm or attempt to tamper with it. This will invalidate the
guarantee, but more importantly may expose the user to shock or fire hazards.
This guarantee is in addition to your statutory rights as a consumer.
Model, type and classification
The information is available at the back of the smoke alarm.
Product disposal and recycling information
The symbol to the left means that according to local laws and regulations your
product should be disposed of separately from household waste. When this product
reaches its end of life, take it to a collection point designated by local authorities.
Battery disposal information
This symbol indicates that the product contains batteries that according to local
laws and regulations must be disposed of separately from household waste. Take
used batteries to a collection point designated by local authorities.
The European Union - declaration of conformity
Hereby, Bellman & Symfon AB, declares that this product has been tested and
approved to the requirements set out in the following standards:
BS EN14604:2005 + AC:2008, EN 55011:2009 + A1:2010, EN 301 489-1 v1.9.2,
EN 301 489-3 v1.4.1, EN 60601-1-2:2015 (4
th
Edition). The declaration of performance may
be consulted at www.bellman.com.