background image

24

25

TROUBLESHOOTING

PLEASE CHECK THE FOLLOWING POINTS BEFORE 

REQUESTING REPAIR SERVICE.

Self-Diagnosis Table 

Please refer to the following table and inform the exact status when 
requesting repair service.

PROBLEM

CHECK LIST

Completely out of order

 

Check if the power plug is not connected

 

Check if the power supply or outlet  
has failed

Water does not spray out

 

Check if the water supply is turned on

 

Check if water valve is open

 

Check if nozzle is blocked by  
foreign material

 

Check if connection hose is bent

Water pressure is low

 

Check if screen filter is blocked and  
clean if needed. 

 

Check if the water pressure is set at 
too low level.

Water is not  

warm enough

 

Check if its temperature is set at off or low 
level, or economy mode

Seat is not warm enough

 

Check if its temperature is set at off or low 
level, or economy mode

No

.

Self Diagnosis

Indication

1

Water temp sensor is 

disconnected or not inserted.

LEDs of water low + middle  

level blinking

2

Water temp sensor is  

short-circuited or overheated

LEDs of water high + middle  

level blinking

3

Seat temp sensor is 

disconnected or not inserted

LEDs of water low level blinking

4

Seat temp sensor is  

short-circuited or overheated

LEDs of water high level blinking

SETTINGS

 

The unit will work without sitting on the seat if the occupied seat sensor  
is deactivated. (Turned off)

 

If the seat sensor is deactivated, some features cannot be controlled.  
(Night light on/off, silent mode on/off, and nozzle cleaning)

USER SETTING WITH THE REMOTE CONTROL

No.  Function

Seat 

Status

Switch 

 Operation

Description

Initial  

Status

1

Silent 

mode

“   ” For 

longer than 3 

seconds

To turn on/off the 

operating chime 

sound. 

ON

2

Power off

“   ” For 

longer than 3 

seconds

Press one of Stop, 

Wash, Bidet, Intensive 

or Dry  

to power on

3

Seat sensor 

bypass

“   ” For 

longer than 3 

seconds

Seat sensor feature 

will  

be deactivated

OFF

4

Night light

“   ” For 

longer than 3 

seconds

To turn on/off the 

night light

ON

5

Factory 

reset

Press and 

hold the Stop 

button for  

5 seconds

After 3 seconds, the 

seat will power off. 

Keep holding  

another 2 seconds and 

the seat will power 

back on.  

This completes the 

 factory reset process

ON

Seat sensor ‘off’

Seat sensor ‘on’

Regardless of on/off

Summary of Contents for bioBidet SLIM ONE

Page 1: ...OWNER S MANUAL SLIM ONE ...

Page 2: ...INFORMATION Safety Precautions 4 Parts 8 Product 9 Dimensions 10 Remote Control 11 INSTALLATION Installation 12 HOW TO USE How to Use 14 Maintenance Cleaning 22 Settings 24 Troubleshooting 25 Specifications 26 WARRANTY Warranty 27 ...

Page 3: ... can fall or be pulled into a tub or sink Do not place in or drop into water or other liquid Do not reach for a product that has fallen into water Unplug immediately WARNING TO REDUCE THE RISK OF BURNS ELECTROCUTION OR INJURY TO PERSONS Close supervision is necessary when this product is use by on or near children Use this product only for its intended use as described in this manual Only use atta...

Page 4: ...nding instructions are not completely understood or if in doubt as to whether the product is properly grounded This product is for use on a nominal 120V circuit and has a grounding plug that looks like the plug illustrated in sketch A in Figure 1 A temporary adapter which looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2 pole receptacle as shown in sket...

Page 5: ...8 9 PARTS Water supply hose PRODUCT ...

Page 6: ...TEMP NOZZLE CLEANING ENERGY SAVING WATER TEMP CHILD WASH To run the bidet function 1 minute To run the turbo function 1 minute To control the nozzle position To run the pulse function during wash bidet turbo operation Selecting nozzle cleaning while not seated the nozzle cleans itself 3 times Then nozzle extends and stop for manual cleaning process Children safety and automatic mode Night light Pr...

Page 7: ...wards the toilet tank Push it until you hear a click When the product is not installed well it may cause leakage Adjust as needed before tightening bolts Do not over tighten the bolts 4 Push the main body toward the catch plate completely Align Align Removal of Removal of water hose water hose Installation Installation of T valve of T valve 5 Connect bidet hose 6 Turn on the water After installing...

Page 8: ...Turbo function helps relieve constipation 1 Sit On The Toilet Seat When pressing the Pulse button during the operation of Wash Bidet and Turbo water pressure will repeat high and low for smooth pulsating wash Pulse function will not operate during the operation of Sitz bath See page 17 step 14 When selecting Child Function settings adjust to low pressure 1 min Bidet 30 sec Bidet Oscillating 30 sec...

Page 9: ...the water and screens filters All operations will stop When pressing the stop button for 3 seconds unit will turn off Press Stop Wash Bidet or Turbo to turn on Seat temperature is adjustable 4 levels Off Low Middle High To reduce the chance of low temperature burns the seat has a safety feature that turns to low temperature 35 C 95 F when seat is occupied for more than 15 minutes consecutively If ...

Page 10: ...the seat and water temperature are off they will remain off When selecting Nozzle Cleaning while not seated the nozzle cleans itself 3 times Then nozzle extends and stop for manual cleaning process Clean the nozzle with a brush and press the STOP button after completion of manual cleaning Then nozzle cleans itself for 3 times and retracts NOZZLE CLEANING will not operate if the seat sensor is acti...

Page 11: ...olled Those features are Night light Silent mode and Nozzle cleaning Press and hold the Stop button for 5 seconds After 3 seconds the seat will power off Keep holding another 2 seconds and the seat will power back on This completes the factory reset process Use of external water filter is only recommended in areas with known hard water issues If a filter is used it must be replaced every 3 months ...

Page 12: ...ng the power plug from the outlet Be sure no water splashes into the power plug or outlet 4 Be careful of not dropping any chemical detergents or toilet cleaner on the main body or supply hose to avoid damage 1 Remove the power plug from the outlet 2 Close the water feed valve 3 Press the release button and gently pull to remove the unit from the catch plate 4 Use a flat head screwdriver to open t...

Page 13: ...uited or overheated LEDs of water high middle level blinking 3 Seat temp sensor is disconnected or not inserted LEDs of water low level blinking 4 Seat temp sensor is short circuited or overheated LEDs of water high level blinking SETTINGS The unit will work without sitting on the seat if the occupied seat sensor is deactivated Turned off If the seat sensor is deactivated some features cannot be c...

Page 14: ...2 m Water feed method Directly connects to water pipe Recommended inlet water pressure 99 106 6 psi Wash Feed Volume Wash 0 13 0 21 gal min Bidet 0 13 0 18 gal min Turbo 0 13 0 18 gal min Child 0 13 0 16 gal min Pressure control 5 levels Temperature control 4 levels off low middle high Heater capacity 800W Safety device Water level sensor Thermal fuse Bi metal Temperature sensor Heated Seat Temper...

Page 15: ...Thank You Technical Support Customer Service 7900 S Route 31 Crystal Lake IL 60014 T 845 458 2334 U S TOLL FREE 877 339 5214 support biobidet com www biobidet com ...

Reviews: