background image

23

22

MAINTENANCE & CLEANING

1.  Close the water valve.

2.  Disconnect the water  

supply hose. Take the  
screen filter out and clean 
 it with a soft brush.

3.  Return the filter after 

cleaning and reconnect the 
water supply hose.

4.  Open the water valve.

1.  Exterior surface of unit is 

made of plastic material, 
which may be damaged by 
scrubber, chemicals, etc.

2.  Wipe the surface with a  

soft damp cloth. Do not 
spray water directly onto 
the surface.

3.  Clean the body after 

removing the power plug 
from the outlet. Be sure 
no water splashes into the 
power plug or outlet.

4.  Be careful of not dropping 

any chemical detergents  
or toilet cleaner on the main 
body or supply hose to  
avoid damage.

1.  Remove the power plug  

from the outlet. 

2.  Close the water feed valve.

3.  Press the release button and 

gently pull to remove the unit 
from the catch plate.

4.  Use a coin to open the  

drain plug.

 

When bidet seat is not used 
for an extended period of time, 
unplug and drain the unit.

Screen Filter Cleaning

Maintenance During Winter

Cleaning the Unit

Draining of Remaining Water

OR

Water supply hose

Screen filter

Summary of Contents for BIOBIDET SLIM TWO

Page 1: ...OWNER S MANUAL SLIM TWO ...

Page 2: ...ON Safety Precautions 4 Parts Dimensions 8 Product 9 Remote Control 10 PRODUCT INSTALLATION Product Installation 11 PRODUCT OPERATION How to Use 14 Maintenance Cleaning 22 Settings 24 Troubleshooting 25 Specifications 26 WARRANTY Warranty 27 ...

Page 3: ... can fall or be pulled into a tub or sink Do not place in or drop into water or other liquid Do not reach for a product that has fallen into water Unplug immediately WARNING TO REDUCE THE RISK OF BURNS ELECTROCUTION OR INJURY TO PERSONS Close supervision is necessary when this product is use by on or near children Use this product only for its intended use as described in this manual Only use atta...

Page 4: ...g instructions are not completely understood or if in doubt as to whether the product is properly grounded This product is for use on a nominal 120V circuit and has a grounding plug that looks like the plug illustrated in sketch A in Figure 1 A temporary adapter which looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2 pole receptacle as shown in sketch B...

Page 5: ...9 8 PARTS DIMENSIONS PRODUCT ELONGATED TYPE ...

Page 6: ... and then remove the seat and cover Store the seat in a proper place for future use Turn off the water Remove the existing water hose and then install T valve to the bottom of the toilet tank Ensure the rubber washer is properly seated and attach the original water hose to the T Valve 2 Install the T Valve ...

Page 7: ... the nozzle comes out and retracts when powered on Do not plug the power cord with wet hands Risk of electric shock Insert the included batteries inside the battery compartment Identify a location in the bathroom for the remote control that is visible and reachable from the toilet PRODUCT INSTALLATION CONT 3 Fix the bracket onto the toilet Point the arrow on the catch plate towards the toilet tank...

Page 8: ...wer water pressure lower seat temperature lower water temperature 3 Massage 4 Child Function Be sure to sit on the seat sensor If the sensor is not occupied all functions will not operate Skin to seat contact needs to occur to activate seat Selected function can be used as described When pressing the selected function again the nozzle will oscillate back and forth to wash a wider range Press the b...

Page 9: ...s filters All operations will stop When pressing the stop button for 3 seconds unit will turn off Press any of Stop Wash Bidet or Turbo to turn on Seat temperature is adjustable 4 levels Off Low Middle High To reduce the chance of low temperature burns the seat has a safety feature that turns to low temperature 35 C 95 F when seat is occupied for more than 15 minutes consecutively If the seat is s...

Page 10: ...are off they will remain off When selecting Nozzle Cleaning while not seated the nozzle cleans itself 3 times Then the nozzle extends and stops for manual cleaning process Clean the nozzle with a brush and press the STOP button after completion of manual cleaning Then the nozzle cleans itself for 3 times and retracts NOZZLE CLEANING will not operate if the seat sensor is activated 11 Night Light 1...

Page 11: ... Silent mode and Nozzle cleaning 15 Reset Using Inline Carbon Filter Press and hold the Stop button on the auxiliary panel for 5 seconds After 3 seconds the seat will power off Keep holding another 2 seconds and the seat will power back on This completes the factory reset process Use of external water filter is only recommended in areas with known hard water issues If a filter is used it must be r...

Page 12: ...n the body after removing the power plug from the outlet Be sure no water splashes into the power plug or outlet 4 Be careful of not dropping any chemical detergents or toilet cleaner on the main body or supply hose to avoid damage 1 Remove the power plug from the outlet 2 Close the water feed valve 3 Press the release button and gently pull to remove the unit from the catch plate 4 Use a coin to ...

Page 13: ...ut sitting on the seat if the occupied seat sensor is deactivated Turned off If the seat sensor is deactivated some features cannot be controlled Night light on off silent mode on off and nozzle cleaning USER SETTING WITH THE REMOTE CONTROL No Function Seat Status Switch Operation Description Initial Status 1 Silent mode For longer than 3 seconds To turn on off the operating chime sound ON 2 Seat ...

Page 14: ...ater feed method Directly connected to water pipe Recommended inlet water pressure 99 106 6 psi Wash Feed Volume Wash 0 13 0 21 gal min Bidet 0 13 0 18 gal min Turbo 0 13 0 18 gal min Child 0 13 0 16 gal min Pressure control 5 levels Temperature control 4 levels off low middle high Heater capacity 800W Safety device Water level sensor Thermal fuse Bi metal Temperature sensor Heated Seat Temperatur...

Page 15: ...Thank You Technical Support Customer Service 7900 S Route 31 Crystal Lake IL 60014 T 847 458 2334 U S TOLL FREE 877 339 5214 support biobidet com www biobidet com ...

Reviews: