24
25
TROUBLESHOOTING
PLEASE CHECK THE FOLLOWING POINTS
BEFORE REQUESTING REPAIR SERVICE.
USER SETTINGS WITH SIDE CONTROL (AUXILIARY PANEL)
Problem
Check list
Completely
out of order
• Check if the power plug is not connected
• Check if the power supply or outlet has failed
Water does not
spray out
• Check if the water supply is turned on
• Check if water valve is open
• Check if nozzle is blocked by foreign material
• Check if connection hose is bent
Water pressure
is low
• Check if screen filter is blocked and by
foreign material
• Check if the water pressure is set at too low level
Water is not
warm enough
• Check if its temperature is set at off or low level
Seat is not warm
enough
• Check if its temperature is set at off or low level
SETTINGS
•
The unit will work without sitting on the seat if the occupied seat sensor is
deactivated. (Turned off)
•
If the seat sensor is deactivated, some features cannot be controlled.
(Night light on/off, silent mode on/off, and nozzle cleaning)
USER SETTING WITH THE REMOTE CONTROL
No.
Function
Seat
Status
Switch
Operation
Description
Initial
Status
1
Silent
mode
“ ” For
longer than 3
seconds
To turn on/off
the operating
chime sound.
ON
2
Seat
sensor
bypass
“ ” For
longer than 3
seconds
Seat sensor feature
will be deactivated.
OFF
3
Night
light
“ ” For
longer than 3
seconds
To turn on/off the
night light.
ON
Seat sensor ‘off’
Seat sensor ‘on’
No.
Function
Seat
Status
Switch
Operation
Description
Initial
Status
1
Factory
reset
Press and
hold the Stop
button for
5 seconds.
After 3 seconds,
the seat will
power off. Keep
holding another
2 seconds and the
seat will power back
on. This completes
the factory
reset process.
ON
2
Power off
“ “ for
longer than 3
seconds
Press one of Stop,
Wash, Bidet,
Intensive or Dry to
power on.