Mounting, connection and commissioning
20
CP9xx_D00349_08_M_XXEN/02.2022
4.2.1
Continuation of CP915 or CP924 installation
1. Connect the front plate to the control board and the power supply unit:
Connect a USB port
(8)
to the board for the touch sensor connection on the front plate. Appro-
priate connecting cable included in scope of delivery.
2. Connect the screen output DVI
(9)
to the front plate.
DVI cable: Cable length < 3 m, connect firmly to PE on both sides. Appropriate DVI-D connect-
ing cable included in scope of delivery.
3. Connect the voltage supply to the power supply unit via the pre-assembled wiring. Connect
the earthing to the front plate.
8
USB connection control board
Touch sensor connection
Front plate
9
DVI-D connection control board
Pre-assembled voltage supply