background image

Technical data

34

CP9xx_D00349_08_M_XXEN/02.2022

Dimensions

 CP907 (W x H x D)...................................................................................................................... 226 x 144 x 78 mm
 CP915 (W x H x D)...................................................................................................................... 505 x 350 x 92 mm
 CP924 (W x H x D).................................................................................................................... 654 x 441 x 100 mm

Weight

CP907 ...................................................................................................................................................approx. 1.1 kg
CP915 ...................................................................................................................................................approx. 6.1 kg
CP924 ..................................................................................................................................................approx. 9.1 kg

( )* = factory setting

8.2

Standards, approvals and certifications 

8.3

Ordering details

Complete devices

Scope of delivery: display unit, flush-mounting enclosure incl. mounting plate with electronics, 
CP9xx connecting cable and plug kit

Individual components

Type

Display size

Supply

Device 

dimensions 

(W x H x D)

Weight

Front

glass, 

tempered

Art. No.

CP907

7" (17.6 cm)

DC 24 V, < 15 W; 

alternatively PoE possi-

ble 

226 x 144 x 78 mm

1.1 kg

white

B95061080

CP907 with-

out flush-

mounting 

enclosure

0.9 kg

white

B95061093

CP915

15.6" (39.6 cm)

AC 100…240 V, < 30 W

505 x 350 x 92 mm

6.1 kg

white

grey

B95061081
B95061085

CP924

24" (61 cm)

AC 100…240 V, < 55 W

654 x 441 x 100 mm

9.1 kg

white

grey

B95061083
B95061084

Device series

Accessories

Art. No.

CP907

Flush-mounting enclosure

B95100140

CP915

Display unit, white

B95061090

Display unit, grey

B95061110

CP924

Display unit, white

B95061097

Display unit, grey

B95061111

CP907 only
B95061080

Summary of Contents for B95061080

Page 1: ...Manual EN CP9xx_D00349_08_M_XXEN 02 2022 COMTRAXX CP9xx Control Panel Remote alarm indicator and operator panel for medical locations and other areas Softwareversion V4 5 x ...

Page 2: ...g only with permission of the publisher Subject to change Bender GmbH Co KG PO Box 1161 35301 Grünberg Germany Londorfer Straße 65 35305 Grünberg Germany Tel 49 6401 807 0 Fax 49 6401 807 259 E mail info bender de www bender de Photos Bender Archive ...

Page 3: ...cal installations 9 2 3 Intended use 9 3 Product description 10 3 1 Scope of delivery 10 3 2 Device features 10 3 3 Possible applications 11 3 4 Configuration diagnosis service 11 3 5 Optional accessories 11 3 6 Software products used 11 3 7 Applications 12 3 8 Functional description 12 3 8 1 Interfaces 12 3 8 2 Process image 13 3 8 3 Control of operating theatre lights 13 4 Mounting connection an...

Page 4: ...ta access via PROFINET 26 5 2 Device assignment for PROFINET 26 5 3 Data modules 27 5 4 Example of a data query 27 6 Modbus TCP server 28 7 Troubleshooting 29 7 1 Malfunctions 29 7 1 1 What should be checked 29 7 1 2 Frequently asked questions 29 7 2 Maintenance 29 7 3 Cleaning 29 8 Technical data 30 8 1 Tabular data 30 8 2 Standards approvals and certifications 34 8 3 Ordering details 34 8 4 Docu...

Page 5: ...ed explanations in the related specialist literature and on the Internet BCOM Protocol for communication of Bender devices via an IP based network BMS Bender measuring device interface RS 485 interface with BMS protocol Always keep this manual within easy reach for future reference To make it easier for you to understand and revisit certain sections in this manual we have used symbols to identify ...

Page 6: ...Telephone 49 6401 807 760 Fax 49 6401 807 259 In Germany only 0700BenderHelp Telephone and Fax E mail support bender service de 1 2 2 Repair service Repair calibration update and replacement service for Bender products Repair calibration testing and analysis of Bender products Hardware and software update for Bender devices Delivery of replacement devices in the event of faulty or incorrectly deli...

Page 7: ...s The conditions of sale and delivery set out by Bender apply For software products the Softwareklausel zur Überlassung von Standard Software als Teil von Lieferungen Ergänzung und Änderung der Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroin dustrie software clause in respect of the licensing of standard software as part of deliveries modifications and changes to general...

Page 8: ... Furthermore the rules and regulations that apply for accident prevention at the place of use must be ob served 1 7 Disposal Abide by the national regulations and laws governing the disposal of this device Ask your supplier if you are not sure how to dispose of the old equipment The directive on waste electrical and electronic equipment WEEE directive and the directive on the restriction of certai...

Page 9: ... RTU or Modbus TCP interface Other devices with Modbus RTU or Modbus TCP interface In addition the data is available via the Modbus TCP protocol This allows coupling to a higher level building control system as well as visualisation and evaluation using standard web browsers Operation and settings are made via the COMTRAXX user interface integrated in the device Any other use than that described i...

Page 10: ...nd CP924 Connecting cables video cable Ethernet keystone coupler USB cable RJ45 flat patch cable 3 2 Device features Universal alarm indicator and operator panel for Bender systems Display sizes 7 15 and 24 with tempered and anti reflective glass Easy to clean and disinfect degree of protection IP54 Screwless mounted front plate User friendly touch sensitive monitoring system for medical locations...

Page 11: ...ng voltages capacities measurement signals or special functions into the alarm indicator and operator panel Communication with building management systems via common interfaces such as Modbus TCP Modbus RTU Profibus KNX LonWorks Sercos interface InterBus Dali CANopen Ehter Net IP CC Link DeviceNet BACnet Profinet The result is an all round system that is both modular and flexible and can thus be a...

Page 12: ...nd systems assigned via various interfaces Internal BMS bus RS 485 for Bender systems such as EDS46 49 RCMS46 49 and MEDICS CP9xx devices can be operated as a master or as a slave When operated as a master requests are answered more quickly The devices can only be operated on the internal BMS bus BCOM Ethernet for new and future Bender systems such as ISOMETER iso685 D Modbus RTU RS 485 when opera...

Page 13: ...ost operat ing theatre lights feature a USB or RS 232 interface The CP9xx can be connected via this interface RS 232 interfaces require a converter from RS 232 to USB The control and the communication pro tocol was tested and verified together with the operating theatre light manufacturers The functionality and design of the CP9xx controls are adapted to that of the operating theatre lights The op...

Page 14: ...be earthed Without connection of the functional earth the device function is not guaranteed Electrostatic sensitive components Observe the precautions for handling electrostatic sensitive devices Damage to components Do not remove the device from the enclosure while it is in operation Disconnect the device from the supply voltage and from the network Ethernet beforehand Damage to the device due to...

Page 15: ...ucture The enclosure must not warp during mounting The wall surface must be even Tightening torque The tightening torque for the mounting screws may be in a range between 0 8 1 Nm Device dimensions Type Dimensions mm 1 a b c CP907 226 144 176 7 CP915 505 350 386 15 6 CP924 654 441 610 24 Installation dimensions enclosure Type Enclosure Dimensions mm Required installation depth a b CP907 Flush moun...

Page 16: ...nd and screw it in place using the fasteners of the flush mounting enclosure 3 Make the required cable openings in both enclosures 4 Connect the CP907 and mount it in the enclosure 4 1 4 Flush mounting enclosure CP915 CP924 Fig 4 3 Flush mounting enclosure CP915 CP924 Mounting of flush mounting enclosures The supplied flush mounting enclosures are only suitable for mounting in cavity walls In dryw...

Page 17: ... display Configuration of computer networks If you arefamiliar withtheconfiguration ofcomputernetworks you can carryouttheconnec tion of the CP9xx yourself Otherwise please contact your IT administrator Ethernet The shield of the Ethernet cable must be connected to PE on both sides For UL applications CP907 only Use copper lines only Minimum temperature range of the wires to be connected to the pl...

Page 18: ... 6 to the BMS bus A to A B to B No Connection No Connection 1 Plug connector digital inputs 7 Termination of Modbus RTU and BMS bus 2 I C interface 8 USB ports for touch sensor 3 Plug connector to energy storage board 9 DVI output CP907 not included 4 Voltage supply A1 A2 PE 10 Audio output 5 Ethernet RJ45 CAT5 HTTP Modbus TCP BCOM CP907 only with PoE 11 Audio input not included 6 X1 plug connecto...

Page 19: ...l earth The device must be earthed Without connection of the functional earth the de vice function is not guaranteed Electrostatic sensitive components Observe the precautions for handling electrostatic sensitive devices Damage to components Do not remove the device from the enclosure while it is in operation Disconnect the device from the supply voltage and from the network Ethernet beforehand Da...

Page 20: ... priate connecting cable included in scope of delivery 2 Connect the screen output DVI 9 to the front plate DVI cable Cable length 3 m connect firmly to PE on both sides Appropriate DVI D connect ing cable included in scope of delivery 3 Connect the voltage supply to the power supply unit via the pre assembled wiring Connect the earthing to the front plate 8 USB connection control board Touch sens...

Page 21: ... behind the upper snap locks of the flush mounting enclosure see red markings Lower the display and slide it into the flush mounting enclosure 5 When pushing in the display the spring force of the snap locks must be overcome Make sure that no wiring gets jammed in the process 6 When removing the display unit it is important that you only place the suction lifter in the side area of the display and...

Page 22: ...l inputs DI1 12 the following can be set An event is executed when the digital input experiences an edge change The edge change must be present at least for the set response delay ton otherwise it is ignored Parameter Options Setting range Mode Active high Active low Impulse active high Impulse active low Measurement type Operating message Alarm Fault ton Response delay 0 s 10 minutes toff Switch ...

Page 23: ... check box to the right of the DHCP label in line 4 Confirm your selection by pressing the Save button The network settings transmitted from the server are shown on the display after 8 10 seconds 4 5 COMTRAXX user interface of the CP9xx The device has a web user interface for setting and operation How to start the web interface Open an Internet browser from any network device Enter the address of ...

Page 24: ...ber of faults COMTRAXX documentation Further information on functionality and configuration of the CP9xx can be found in the manual D00418 Parameter Factory setting Parameter Factory setting IP address toff Timeout for DCHP address assign ment 30 s IP address for 1 1 ETH conn 169 254 0 1 BMS address 1 Net mask 255 255 0 0 BMS protocol BMS i Standard gateway 192 168 0 1 BCOM system name SYSTEM DNS ...

Page 25: ...mands are issued Please note that not all BMS masters can surrender their master function Multiple assignment of addresses The factory setting for the system name on all Bender BCOM devices is SYSTEM If several systems with the same system name are integrated into the same net work addresses are assigned twice This leads to transmission errors Always en ter a unique BCOM system name during initial...

Page 26: ...INET device names this can also be done via the PLC or similar system Provision of GSDML file The GSDML file is also available in the download area of our homepage at https www bender de en Service sup port Downloads Software 5 2 Device assignment for PROFINET To make the required measured values or alarm states available via PROFINET a device assignment must be generated for the PROFINET image Th...

Page 27: ... device assignment of the COMTRAXX device Tools Device management Device assignment PROFINET and click on the Add entry button Select slot and channel in the pop up dialogue and confirm with Ok The measuring channel now appears in the table and can be accepted with the Save changes button The configuration of the COMTRAXX device is now complete and the measuring channel can be read on slot 13 Data...

Page 28: ...n code 0x03 Read Holding Registers Function code 0x04 Read Input Registers Function code 0x10 Preset Multiple Registers The Modbus TCP server generates a function related response to requests and sends it back to the Modbus TCP client Detailed information as well as examples on Modbus TCP and system images can be found in the manual D00418 ...

Page 29: ...s the device if the address data are unknown 1 Connect the device directly to a Windows PC using a patch cable 2 Activate the DHCP function on the PC 3 Wait around one minute 4 Access is now possible using the following pre defined IP address 169 254 0 1 5 Now set the new address data Frequently asked questions on the Internet You will find FAQs on many Bender devices at http www bender de en Serv...

Page 30: ...g in terminal A1 A2 Maximum cable length when supplied via B95061210 24 V DC power supply unit 1 75 A 0 28mm 75 m 0 5mm 130 m 0 75mm 200 m 1 5mm 400 m 2 5mm 650 m Supply via PoE CP907 only PoE standard IEEE 802 3at Nominal voltage DC 48 V SELV PELV Nominal voltagetolerance 25 15 Typical power consumption for PoE 15 W Maximum cable length when supplied via AWG 26 7 0 14 mm 100 m Supply CP915 via te...

Page 31: ... 100 m Data rate 10 100 Mbit s autodetect DHCP on off off toff DHCP 5 60 s 30 s IP address nnn nnn nnn nnn 192 168 0 254 can always be reached via 169 254 0 1 Net mask nnn nnn nnn nnn 255 255 0 0 Protocols depending on function module selected TCP IP Modbus RTU DHCP SMTP NTP BMS bus Interface protocol RS 485 BMS internal Operating mode master slave master Baud rate 9 6 kbit s Cable length 1200 m C...

Page 32: ...NET Interface protocol Ethernet PROFINET Operating mode slave IO device Digital inputs 1 12 Number 12 Galvanic separation yes Operating mode selectable for each input active high or active low Factory setting active high Voltagerange high AC DC 10 30 V Voltagerange low AC DC 0 2 V Max current per channel at AC DC 30 V 8 mA Connection push in terminal 1 1 2 2 3 3 12 12 Maximum cable length 1000 m S...

Page 33: ...tic sleeve 0 25 1 5 mm flexible with ferrule with plastic sleeve 0 25 0 75 mm For UL applications CP907 only Use copper lines only Minimum temperature range of the cable to be connected to the plug in terminals 75 C Minimum temperature range of the cable to be connected to the PoE plug 80 C Environment EMC EMC IEC 61326 1 Operating temperature CP907 10 55 C CP907 for UL applications 10 50 C CP915 ...

Page 34: ...l components Type Display size Supply Device dimensions W x H x D Weight Front glass tempered Art No CP907 7 17 6 cm DC 24 V 15 W alternatively PoE possi ble 226 x 144 x 78 mm 1 1 kg white B95061080 CP907 with out flush mounting enclosure 0 9 kg white B95061093 CP915 15 6 39 6 cm AC 100 240 V 30 W 505 x 350 x 92 mm 6 1 kg white grey B95061081 B95061085 CP924 24 61 cm AC 100 240 V 55 W 654 x 441 x ...

Page 35: ...CP924 CP9xx suction lifter 1 B95061911 All CP9xx replacement plug kit B95061910 Date Document version Valid from software version State Changes 02 2022 08 4 5 x Editorial revision chapter 4 Indications connection Ethernet and PoE connections main board chapter 6 Reference to D00418 chapter 8 Cable recommendations and lengths Added chapter 4 1 chapter 8 3 Surface mounting enclosure CP907 chapter 5 ...

Page 36: ...Technical data 36 CP9xx_D00349_08_M_XXEN 02 2022 ...

Page 37: ... 9 Disposal 8 F Factory settings communication addresses Communication addresses 24 G GSD file 28 I Installation and connection 14 Installation preliminary considerations 14 Intended use 9 M Malfunctions 29 Q Qualified personnel 9 14 R Repair 6 S Service 6 Sketch with dimensions 34 SNMP 26 Storage 7 Support 6 T Training courses 7 W WEEE directive 8 Workshops 7 Index ...

Page 38: ......

Page 39: ......

Page 40: ...ender GmbH Co KG PO Box 1161 35301 Grünberg Germany Londorfer Straße 65 35305 Grünberg Germany Tel 49 6401 807 0 Fax 49 6401 807 259 E Mail info bender de www bender de Photos Bender Archive BENDER Group ...

Reviews: