CC613-Hxx_D00423_02_M_XXEN/11.2020 23
CC613-Hxx charge controller
Inputs
Weld check (terminal H (WB, WA))
Input voltage ................................................................................................................................................................ AC 180 V…277 V
Input current ........................................................................................................................................................................0.6…1.3 mA
Input PE (terminal B (PE, PE))
Outputs
Contact data acc. to IEC 60947-5-1:
Switching contact for contactor (terminal H (relay 23, relay 24))
Rated operational voltage U
e
..................................................................................................................................................... AC 230 V
Rated operational current I
e
.......................................................................................................................................................... AC 4 A
Minimum contact rating .........................................................................................................................................50 mA at ≥ 10 V (AC)
Environment/EMC
EMC ...............................................................................................................................................................................see CE declaration
Operating temperature .......................................................................................................................................................-30…+70 °C
Classification of climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3). ................................................................................... 3K23 (except condensation and formation of ice)
Transport (IEC 60721-3-2) ................................................................................................................................................................ 2K11
Long-term storage (IEC 60721-3-1) .................................................................................................................................................. 1K21
Classification of mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ........................................................................................................................................................ 3M11
Transport (IEC 60721-3-2) ................................................................................................................................................................. 2M4
Long-term storage (IEC 60721-3-1) ................................................................................................................................................ 1M12
Cable lengths/cable types
Ethernet (terminal D)
Connection cable ..............................................................................................................................................................................CAT 6
Max. connection cable length ........................................................................................................................................................ 100 m
Connection type (terminal blocks B and J) ������������������������������������������������������������������������������������������������push-wire terminal
Connection specifications:
rigid /flexible ........................................................................................................................................... 0.2…1.5 mm² (AWG 24…16)
flexible with ferrule without plastic sleeve ..............................................................................................0.25...1.5 mm² (AWG 24…16)
flexible with ferrule with plastic sleeve .................................................................................................0.14...0.75 mm² (AWG 26…18)
Stripping length ............................................................................................................................................................................. 10 mm
Max. connection cable length ............................................................................................................................................................ 2 m
Cross-section ............................................................................................................................................................................≥ 0.5 mm2
Max. connection cable length (PE) ..................................................................................................................................................... 4 m
Cross-section (PE) .......................................................................................................................................................................≥ 1 mm2
Connection type (terminal H) �������������������������������������������������������������������������������������������������������������������push-wire terminal