OPERATION & LEAKAGE TESTS (REFER TO THE 
TROUBLESHOOTING CHART IN THIS MANUAL)

For additional information see video BW2237.

1.  Check all lines and fi ttings leading to and from the air 

dryer and reservoir system for leakage and integrity.  
Repair any leaks found.

2.  Build up system pressure to governor cut-out and note 

that the Bendix

®

 AD-IS

®

 air dryer purges with an audible 

escape of air. Watch the system pressure and note the 
pressure fall-off for a ten minute period.  If pressure 
drop exceeds—a) for a single vehicle: 1 psi/minute 
from either service reservoir; or b) for tractor trailer: 3 
psi/minute from either service reservoir—inspect the 
vehicle air systems for leak sources and repair them.  
Refer to the Symptoms 1 and 4 in the Troubleshooting 
Chart.

3. 

Caution:  Be sure to wear safety glasses in case 
of a purge blast. 

Check for excessive leakage around 

the purge valve with the compressor in the charge mode 
(compressing air).  Apply a soap solution to the purge 
valve exhaust port and observe that leakage does not 
exceed a 1" bubble in one second.  If any leakage 
exceeds the maximum specifi ed, refer to Symptom 4 
in the Troubleshooting Chart.

4.  Build up system pressure to governor cut-out and note 

that the AD-IS air dryer purges with an audible burst of 
air, followed immediately by approximately 30 seconds 
of air fl owing out of the purge valve.  "Fan" the service 
brakes to reduce system air pressure to governor 
cut-in.  Note that the system once again builds to full 
pressure and is followed by a purge. If the system does 
not follow this pattern, refer to Symptoms 5 and 6 in 
the Troubleshooting Chart .

5.  Check the operation of the end cover heater and 

thermostat assembly during cold weather operation as 
follows:

A.  Electric Power to the Dryer (Refer to Figure 4.)

 

With the ignition or engine kill switch in the RUN 
position, check for voltage to the heater and 
thermostat assembly using a voltmeter or test light.  
Unplug the electrical connector at the air dryer and 
reservoir system and place the test leads on each 
of the connections of the female connector on the 
vehicle power lead.  If there is no voltage, look for a 
blown fuse, broken wires, or corrosion in the vehicle 
wiring harness.  Check to see if a good ground path 
exists.

B.  Thermostat and Heater Operation

 

Note: These tests are not possible except in cold 
weather operation.

 

Turn off the ignition switch and cool the thermostat 

and heater assembly to below 40° Fahrenheit.  Using 
an ohmmeter, check the resistance between the 
electrical pins in the air dryer and reservoir system 
connector half.  The resistance should be 1.5 to 3.0 
ohms for the 12 volt heater assembly, and 6.0 to 9.0 
ohms for the 24 volt heater assembly.

 

Warm the thermostat and heater assembly to 
approximately 90° Fahrenheit and again check the 
resistance. The resistance should exceed 1000 
ohms. If the resistance values obtained are within 
the stated limits, the thermostat and heater assembly 
is operating properly.  If the resistance values 
obtained are outside the stated limits, replace the 
heater and thermostat assembly.

6.  Pressure Protection Valves.  Observe the pressure 

gauges of the vehicle as system pressure builds from 
zero.  The primary or secondary gauge should rise until 
it reaches approximately 106 psi (±6 psi), then level 
off (or a momentary slight fall) as the next pressure 
protection valve opens—supplying its reservoir.  When 
that pressure gauge passes through approximately 106 

FIGURE 5 - PRESSURE PROTECTION VALVE LOCATIONS

PRESSURE 

PROTECTION 

VALVE 

LOCATIONS

THE BENDIX

®

 AD-IS

®

AIR DRYER GOVERNORS ARE 

NON-ADJUSTABLE

AND FEATURES A BREATHER 

VALVE IN THIS PORT

WARNING:

DO NOT ATTEMPT TO ADJUST OR 

SERVICE THE PRESSURE PROTECTION 

VALVES.  INCORRECT PRESSURE 

PROTECTION VALVE SETTINGS CAN 

RESULT IN AUTOMATIC APPLICATION 

OF VEHICLE SPRING BRAKES WITHOUT 

PRIOR WARNING.

Summary of Contents for AD-IS -

Page 1: ...and Reservoir Systems DESICCANT CARTRIDGE PURAGUARD OIL COALESCING SHOWN PURGE RESERVOIR 24 AUX1 AUXILIARY DELIVERY PORTS 4 GOVERNOR PRESSURE PROTECTION VALVES 4 HEATER THERMOSTAT SAFETY VALVE AIR DRY...

Page 2: ...in the other reservoir or a pressure loss in an air accessory Each of the pressure protection valves in the AD IS air dryer and reservoir systems may have different pressure settings These are factor...

Page 3: ...ure that is designed to prevent loss of engine turbo boost pressure during the purge cycle of the Bendix AD IS air dryer and reservoir system For ease of maintenance all replaceable assemblies can be...

Page 4: ...ompressor activating the purge cycle of the air dryer and reservoir The governor unloads the compressor by allowing air pressure to fill the line leading to the compressor unloader mechanism This susp...

Page 5: ...f temperature occurs in one day small amounts of water can temporarily accumulate in the air brake system due to condensation Under these conditions the presence of small amounts of moisture is normal...

Page 6: ...ch in the RUN position check for voltage to the heater and thermostat assembly using a voltmeter or test light Unplug the electrical connector at the air dryer and reservoir system and place the test...

Page 7: ...ll reservoir drain valves 2 Build up system pressure to governor cut out and note that the Bendix AD IS air dryer purges with an audible burst of air followed immediately by approximately 30 seconds o...

Page 8: ...8 FIGURE 7 SPLASH SHIELD BRACKET AND COVER EXPLODED VIEW SPLASH SHIELD BRACKET SPLASH SHIELD COVER LOCK TABS...

Page 9: ...ocation Note that a short puff of trapped air may vent from the safety valve port when removing the valve Install a T fitting into the port Using any adapters necessary reinstall the safety valve in o...

Page 10: ...ot use solvents 3 Inspect for physical damage to the bore and the check valve seat If the bore is damaged by scratches etc that would prevent delivery check valve from seating replace the AD IS air dr...

Page 11: ...governor cut out and allow a full minute for the normal dryer purge cycle to empty the purge reservoir Switch off the engine and fan the brakes so that the system pressure reaches governor cut in The...

Page 12: ...dryer not purging F Refer to Symptom 6 G Purge air exhaust time insufficient due to excessive system leakage G Refer to Symptom 1 3 Safety valve on air dryer popping off or exhausting air A Defective...

Page 13: ...eing expelled from air dryer purge valve exhaust may look like whitish liquid or paste or small beads A Faulty dryer cartridge A Replace the Bendix AD IS air dryer cartridge or AD IS air dryer B Exces...

Page 14: ...14 BW2234 2011 Bendix Commercial Vehicle Systems LLC a member of the Knorr Bremse Group 07 11 All Rights Reserved...

Reviews: