89000109-002
xVue Touch Installation Manual
Rev 2
Page 5-8
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
5.3.2 KG 71EXP Pressure Ports
The air pressure interface for static and total pressure ports is provided via static and pitot fittings.
Details about the pressure ports are described in Table 5-5 Pressure Port Descriptions. An example of
straight and elbow pressure fittings is depicted in
Figure 5-1 Pressure Port Fitting(s).
Figure 5-1 Pressure Port Fitting(s)
43
A429 TX1 A
Out
44
A429 TX1 B
Out
45
Chassis GND
GND
46
CAN H
In
47
CAN L
In
48
A429 TX2 B
Out
49
Interlock 1
In
50
Interlock 2
In
Table 5-5 Pressure Port Descriptions
Pressure
Name
KG71EXP IPT Adapter Ending
Recommended Fitting
Operational
Pressure Range
Pitot Pressure
Nipple to 1/8 inch, NPT Male
• Straight male AN816-4D
• Elbow male AN822-4D
(1.4 - 37) in Hg
Static Pressure Nipple to 1/8 inch, NPT Male
• Straight male AN816-4D
• Elbow male AN822-4D
(1.4 - 32) in Hg
J71 Pin
Description
I/O
NOTE
THE CONNECTION OF KG 71EXP TO THE ORIGINAL PRESSURE DISTRIBUTION SYSTEM
MUST BE IN COMPLIANCE WITH 14 CFR 23.1323 AND 23.1325.