89000109-002
xVue Touch Installation Manual
Rev 2
Page 7-34
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
7.5.2.2 KSD 100EXP Software Loading Errors
The following error message may appear in the Software Loading Pop-Up Window during the loading
process:
7.5.2.3 KG 71EXP Software Update
The KG 71EXP software cannot be updated in the field. The unit must be returned to BendixKing if an
update is required.
Table 7-5 Software Loading Error
Status Message
Criteria
Corrective Action
File Corrupted
Please re-download
the file and try again
The .tar file is corrupted and cannot
be loaded onto the KSD 100EXP.
Delete the existing .tar file and re-
download a the KSD 100EXP software
onto the USB drive. Restart software
loading process.