89000109-002
xVue Touch Installation Manual
Rev 2
Page 8-7
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
8.2 KSD 100EXP Touch Calibration
8.2.1 KSD 100EXP Manual Touch Calibration
When the manual touch calibration is performed, all touch functionality is disabled except the touches
needed to complete the calibration procedure.
(1) Power on the KSD 100EXP by setting the PFD breaker or turning on the avionics.
(2) Press Enter on the Database Acknowledge Screen, refer to Figure 6-3.
(3) On the KSD 100EXP screen, Figure 7-1, select the Menu button, Figure 7-2, located at the top right
of the screen.
(4) From the Main Menu, Figure 7-6, select the System Tools button.
(5) From the System Tools Menu, Figure 7-13, select the Screen Maint button.
(6) From the Screen Maint Menu, Figure 8-1, select the Manual Touch Calibration button.
Figure 8-1 Screen Maint Menu
(7) The Manual Touch Calibration Menu, Figure 8-2, contains a message box asking the user to
confirm if the manual touch re-calibration procedure can proceed.
Figure 8-2 Manual Touch Calibration Menu
NOTE
TO PROCEED WITHOUT MANUAL TOUCH CALIBRATION, CLOSE THE MANUAL TOUCH
CALIBRATION MENU BY PRESSING THE UP ARROW “^” BUTTON.