89000109-002
xVue Touch Installation Manual
Rev 2
Page 9-6
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
KDC 100EXP Data
Converter
A general visual inspection of the KDC100
EXP Data Converter and the associated
wiring must be performed during each
annual inspection. Visually check wiring for
general condition, routing, chafing, bonding
straps and/or wires and integrity of
clamping and stand-offs. Visually check the
mechanical installation for condition,
including checking the unit and all
mounting brackets for security.
Loose and chafing brackets will increase the
resistance between parts. Check for signs
that the units have not been tampered with
or removed. Inspect and verify the bonding
straps or ground wires are in good
condition, and are not loose or chafing.
Connection points to the units and to the
airframe must be inspected for evidence of
corrosion.
If any of these indications are present, an
electrical bonding test must be performed.
12 months
Table 9-1 ICA Inspection Criteria
xVue Touch System
Component Description
Inspection Requirement
Recommended Minimum
Inspection Interval
Completed