89000109-002
xVue Touch Installation Manual
Rev 2
Page B-3
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
Figure B-3 Weather and Traffic Interconnect Diagram
FDL
987
RX
KGX
150T
KGX
150R
KGX
130T
J1
KGX
130R
KSD 100
yW
J1
J1
J1
J1
J1
WEATHER AND
TRAFFIC
NOTES:
1
Single Conductor Wire
x
All wires shall be 22 AWG unless otherwise noted power wires
x
Wiring shall meet AS22759/16/XX/Y (Where XX is gauge and Y is color)
2
Twisted Shielded Pair/Triplet and Shielded Single Wire
x
All wires shall conform to ANSI/NEMA WC 27500
x
Do not remove any wiring between other active aircraft systems. Leave those systems installed as they are.
3
All shield grounds are to be grounded at the closest grounding point to their respective connectors . This includes connector grounding points.
For metallic backshells with grounding capability, ground shield directly to the backshell.
4
Drawing Symbols:
-
Shielded Twisted Pair
8
UAT_WX_RS232_RX
22
24
22
24
22
24
22
24
22
24
RS232 GND
RS232 TX
26
UAT_WX_RS232_GND
9
UAT_WX_RS232_TX
23
23
23
23
23
RS232 RX