89000109-002
xVue Touch Installation Manual
Rev 2
Page 3-28
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
3.7 Placards and Labels
All placards and labels must be readable in all cockpit lighting conditions. New circuit breakers installed
for the KFD 900 must be labeled as follows:
• “PFD” for the KSD 100EXP and KCP 100EXP
• “ADAHRS” for the KG 71EXP
• “MAG” for the KMG 7010/MD32 and KDC 100EXP
If the installation of the xVue Touch System causes existing placard(s) to be relocated, the new placard(s)
must meet the following requirements:
• The font size of the new placard must be the same size as the original placard
• The color of the new placard must be the same as the color of the original placard
• The text on the new placard must be the same as the text on the original placard
• The new placard must be readable in all lighting conditions
• The new placard must be located within an acceptable location per previous guidance
3.8 Power Distribution
The xVue Touch System can operate on either 14 VDC or 28 VDC. The xVue Touch must be powered from
the airplane’s primary power bus through three independent circuit breakers. All required xVue Touch
System components must be connected to the same power bus. If there is more than one power bus on
the airplane, the xVue Touch System components and the electronic standby instruments should be
connected to the “essential” bus. If the airplane has more than one “essential” bus, the xVue Touch
System components should be connected to one “essential” bus and the electronic standby instruments
connected to the other “essential” bus.
For the KSD 100EXP, a 3 amp circuit breaker is required for 14 VDC installations and a 2 amp circuit
breaker is required for 28 VDC installations. The KCP 100EXP is powered by the KSD 100EXP through this
same circuit breaker. For the KG 71EXP, a 3 amp circuit breaker is required for 14 VDC installations and a
2 amp circuit breaker is required for 28 VDC installations. For the KMG 7010/MD32, a 2 amp circuit
breaker is required for 14 VDC installations and a 1 amp circuit breaker is required for 28 VDC
installations. Refer to Figure B-1
for the connection of the xVue Touch System to the airplane’s power
distribution system.
3.8.1 Circuit Protection
Circuit protection devices for the xVue Touch System shall be manually resettable circuit breakers. The
xVue Touch System components should be connected to individual circuit breakers. Refer to Figure B-1
for details on the electrical installation and circuit breaker ratings.
3.9 Cable and Wiring
Wiring should be installed in accordance with AC 43.13-1B Chapter 11:
• Section 8 – Wiring Installation Inspection Requirements
• Section 10 – Service Loop Harnesses
• Section 11 – Clamping
• Section 15 – Grounding and Bounding
• Section 16 – Wire Marking
Refer to
Section 5 Connector Pinout Information and Appendix B Interconnect Diagrams
System
Interconnect for the appropriate wiring connections to assemble the wiring connector.