view centerline. The acceptable installation location for the KSD 100EXP is to have its AI not dramatically
differ from the location of the original type certificated AI. This is accomplished by installing KSD 100EXP
such that its AI display overlaps the original type certificated “AI” location. The AI area is in the top half of
the KSD 100EXP display as illustrated in Figure 3-4.
The original AI location is illustrated with an outline of the overlaid AI in the figure.
Figure 3-4 KSD 100EXP Location (Attitude Indicator)
3.6.5.2 KSD 100EXP Cooling Considerations
The KSD 100EXP does not require forced air cooling within the unit’s operational temperature range,
provided the following conditions are met:
(1) The minimum separation distance from other active instruments is 0.5 inch (12.7 mm) from the
top or bottom of the KSD 100EXP cutout to the instrument.
(2) The installed location is away from heat sources (including electronic instruments). Heat
generating sources should not be installed below the KSD 100EXP.
(3) Adequate space is provided for installation of cables and connectors.
If the conditions listed above are not met, additional forced air cooling is required and is the
responsibility of the installer.
3.6.6 KCP 100EXP Installation Considerations
3.6.6.1 KCP 100EXP Location
The location of the KCP 100EXP is determined by the technician and must be placed where the pilot can
easily reach and see the panel. The location of the KCP 100EXP control panel will be allocated by the
NOTE
IF THE AIR TEMPERATURE BEHIND THE PANEL IS +130°F (+55°C) OR GREATER, WHEN THE
KSD 100EXP UNIT IS POWERED ON IT IS POSSIBLE FOR THE AIR NEAR THE KSD 100EXP TO
REACH TEMPERATURE OF +160°F (+70°C). IT IS THE INSTALLER’S RESPONSIBILITY TO
EVALUATE THE POSSIBLE IMPACT TO OTHER INSTRUMENTS AND PROVIDE ADDITIONAL
COOLING IF NEEDED. IT IS RECOMMENDED THAT AIR BEHIND THE PANEL BE KEPT
MOVING BY VENTILATION OR A FAN.