background image

1

INSTALLATION AND OPERATION MANUAL

SHIPPING DAMAGE CLAIMS

When this equipment is shipped, title passes to the 

purchaser upon receipt from the carrier. Consequently, 

claims for the material damaged in shipment must be made 

by the purchaser against the transportation company at the 

time shipment is received.

BE SAFE

Your new equipment was designed and built with safety 

in mind. However, your overall safety can be increased by 

proper training and thoughtful operation on the part of the 

operator. DO NOT operate or repair this equipment without 

reading this manual and the  important safety instructions 

shown inside.

1645 Lemonwood Dr.

Santa Paula, CA. 93060, USA

Toll Free 1-800-253-2363

Tel: 1-805-933-9970

Fax: 1-805-933-9160

www.bendpak.com

Keep this operation manual near the 

machine at all times. Make sure that 

ALL USERS  read this manual.

ADJUSTABLE LIMIT 

MICROSWITCH

OPTION FOR BENDPAK HD-9  4-POST LIFTS

PLEASE READ THE ENTIRE CONTENTS OF THIS MANUAL PRIOR TO 
INSTALLATION AND OPERATION. BY PROCEEDING YOU AGREE THAT 
YOU FULLY UNDERSTAND AND  COMPREHEND THE FULL CONTENTS OF 
THIS MANUAL. FORWARD THIS MANUAL TO ALL OPERATORS. FAILURE TO 
OPERATE THIS EQUIPMENT AS DIRECTED MAY CAUSE INJURY OR DEATH.

REV A 08/04/2015

p/n 5900181

Summary of Contents for 5900181

Page 1: ...or repair this equipment without reading this manual and the important safety instructions shown inside 1645 Lemonwood Dr Santa Paula CA 93060 USA Toll Free 1 800 253 2363 Tel 1 805 933 9970 Fax 1 805 933 9160 www bendpak com Keep this operation manual near the machine at all times Make sure that ALL USERS read this manual ADJUSTABLE LIMIT MICROSWITCH OPTION FOR BENDPAK HD 9 4 POST LIFTS PLEASE RE...

Page 2: ...t initial function t Read and follow the safety instructions Keep them readily available for machine operators t Make certain all operators are properly trained know how to safely and correctly operate the unit and are properly supervised t Allow unit operation only with all parts in place and operating safely t Carefully inspect the unit on a regular basis and perform all maintenance as required ...

Page 3: ...microswitch prior to mounting Kit inside the Runway Refer to the wiring diagram on page 4 7 Mount the Limit Switch Kit on the inside of the Run way using the four M6 Bolts Nuts and Washers Make sure the microswitch lever is facing as shown See Fig 1 2 8 Route the electrical cable through the hose retainers on the underside of the Powerside Runway and through the flex hose to the power unit Refer t...

Page 4: ...ards the front of the lift the Cylinder Guide Assembly or the Kit will not function properly 13 Test the kit by raising the lift off of the safeties and continue raising until the Cylinder Guide Assembly Arm contacts the microswitch lever and stops the system If the system does not stop at the maximum desired height lower the lift onto the safeties and check the position of the microswitch It may ...

Page 5: ...3660mm A SHEET 1 OF 1 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN SIZE MATERIAL A 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED NOTE UNLESS OTHERWISE SPECIFIED TM 5210235 HD SERIES ADJUSTABLE LIMIT...

Page 6: ...6 For Parts Or Service Contact BendPak Inc Ranger Products 1645 Lemonwood Dr Santa Paula CA 93060 Tel 1 805 933 9970 Toll Free 1 800 253 2363 Fax 1 805 933 9160 www bendpak com p n 5900181 ...

Reviews: