3
REFER TO THE MANUAL THAT CAME WITH THE
LIFT FOR PROPER SAFETY AND OPERATING
INSTRUCTIONS. READ, FOLLOW AND
UNDERSTAND THE OPERATING MANUAL BEFORE
OPERATING ANY AUTOMOTIVE LIFT
1. With no vehicle loaded on the lift, raise lift all the way
off the ground and rest it on the top safety lock position.
2. Ensure that the lift is resting on the safeties.
3. Disconnect the Hydraulic Power Unit on the lift from
the electrical power source.
4. The Adjustable Limit Microswitch Kit will be installed
on the inside of the Powerside Runway near the ram end
of the Hydraulic Cylinder.
5. Select location for the Limit Switch Kit on the side of
the Runway adjacent to the Hydraulic Power Unit.
5. Once desired location is selected, use the Limit
Switch Bracket mounting holes as guides and drill four
holes in the side of the Runway. (See Fig 1.1)
6. Wire the microswitch prior to mounting Kit inside the
Runway. Refer to the wiring diagram on page 4.
7. Mount the Limit Switch Kit on the inside of the Run-
way using the four M6 Bolts, Nuts and Washers. Make
sure the microswitch lever is facing as shown.
(See Fig 1.2)
8. Route the electrical cable through the hose retainers
on the underside of the Powerside Runway and through
the flex hose to the power unit. Refer to the wiring dia
-
gram on the following page for power unit connection.
DO NOT PROCEED OR GO NEAR THE LIFT WORK
AREA UNLESS VISUAL CONFIRMATION IS MADE OF
ALL SAFETY LOCKS. ALL LOCKS MUST BE ENGAGED
BEFORE PROCEEDING. FAILURE TO COMPLY WITH
THESE INSTRUCTIONS MAY RESULT IN SEVERE
PERSONAL INJURY OR DEATH.
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS WITHOUT
FIRST ENSURING THAT ELECTRICAL POWER HAS
BEEN DISCONNECTED AT THE SOURCE OR PANEL
AND CANNOT BE RE-ENERGIZED UNTIL ALL
MAINTENANCE AND/OR INSTALLATION
PROCEDURES ARE COMPLETED.
ALL WIRING MUST BE PERFORMED
BY A LICENSED ELECTRICIAN.
Fig. 1.1
Fig. 1.2
M6 Hardware