background image

4

9.  Reconnect the Hydraulic Power Unit on the lift to the 

electrical power source.

10. Lower the lift to the nearest safety lock position below 

the maximum desired lift height. (Read and Follow all 

lowering precautions and instructions that came with the 

lift.)

11. Ensure that the lift is resting on the safeties.

12. Adjust the microswitch on the slider bar by loosen-

ing the set screw on the top of the slider block. Slide it at 

least 1” (25mm) past the Cylinder Guide Assembly Arm 

and tighten the screw. 

 

 

NOTE: The microswitch itself must be behind (towards 

the front of the lift) the Cylinder Guide Assembly or the Kit 

will not function properly.

13. Test the kit by raising the lift off of the safeties and 

continue raising until the Cylinder Guide Assembly Arm 

contacts the microswitch lever and stops the system. If 

the system does not stop at the maximum desired height, 

lower the lift onto the safeties and check the position of 

the microswitch. It may be necessary to bend the micro-

switch lever to allow more contact.

WIRING DIAGRAM 

Microswitch

220V Single Phase

DO NOT PROCEED  OR GO NEAR THE LIFT WORK 

AREA UNLESS VISUAL CONFIRMATION IS MADE OF 

ALL SAFETY LOCKS. ALL LOCKS MUST BE ENGAGED 

BEFORE PROCEEDING. FAILURE TO COMPLY WITH 

THESE INSTRUCTIONS MAY RESULT IN SEVERE 

PERSONAL INJURY OR DEATH.

DRAFT

Summary of Contents for 5900181

Page 1: ...or repair this equipment without reading this manual and the important safety instructions shown inside 1645 Lemonwood Dr Santa Paula CA 93060 USA Toll Free 1 800 253 2363 Tel 1 805 933 9970 Fax 1 805 933 9160 www bendpak com Keep this operation manual near the machine at all times Make sure that ALL USERS read this manual ADJUSTABLE LIMIT MICROSWITCH OPTION FOR BENDPAK HD 9 4 POST LIFTS PLEASE RE...

Page 2: ...t initial function t Read and follow the safety instructions Keep them readily available for machine operators t Make certain all operators are properly trained know how to safely and correctly operate the unit and are properly supervised t Allow unit operation only with all parts in place and operating safely t Carefully inspect the unit on a regular basis and perform all maintenance as required ...

Page 3: ...microswitch prior to mounting Kit inside the Runway Refer to the wiring diagram on page 4 7 Mount the Limit Switch Kit on the inside of the Run way using the four M6 Bolts Nuts and Washers Make sure the microswitch lever is facing as shown See Fig 1 2 8 Route the electrical cable through the hose retainers on the underside of the Powerside Runway and through the flex hose to the power unit Refer t...

Page 4: ...ards the front of the lift the Cylinder Guide Assembly or the Kit will not function properly 13 Test the kit by raising the lift off of the safeties and continue raising until the Cylinder Guide Assembly Arm contacts the microswitch lever and stops the system If the system does not stop at the maximum desired height lower the lift onto the safeties and check the position of the microswitch It may ...

Page 5: ...3660mm A SHEET 1 OF 1 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN SIZE MATERIAL A 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED NOTE UNLESS OTHERWISE SPECIFIED TM 5210235 HD SERIES ADJUSTABLE LIMIT...

Page 6: ...6 For Parts Or Service Contact BendPak Inc Ranger Products 1645 Lemonwood Dr Santa Paula CA 93060 Tel 1 805 933 9970 Toll Free 1 800 253 2363 Fax 1 805 933 9160 www bendpak com p n 5900181 ...

Reviews: