PART A: CONFIGURING SETTINGS FOR THE TRACKBOX
40 I/O SETTINGS
D e f i n i n g n o t i f i c a t i o n d e l a y
The device can be configured to allow some millseconds to
pass until the event will be registered or interpreted as a
cause for taking an action. In this case an action, such as
sending status messages and/or logging information, would
take place only in case the temperature exceeds the allowed
temperature and stays up for at least NN millseconds.
Key in the time for allowed delay (4,5) in millseconds. Delay
can be set separately for
High
and
Low
, depending on which
one of the event states is in use. If you have set the pin to
register event states for
Both
directions, you can set values
for both
High
and
Low
.
S e t t i n g r e f e r e n c e v a l u e s
Threshold values must be set separately for high and low
(6).
•For the pins you have set event state
High
: Key in
High ref-
erence value
and
Hysteresis for High limits
.
•For the pins you have set event state
Low
: Key in
Low ref-
erence values
and
Hysteresis for Low limits
.
•For the pins you have set event state
Both
: Key in both
Low
and
High reference values
and
Hysteresis for Low
and
High limits
.
STATUS MESSAGES FOR ANALOGUE
INPUT PINS
A status message is a special short message, which includes
the status message text, additional text information and the
last known position (i.e. coordinates and some other MPTP
information). If the current position information is not
available, the previous coordinates will be sent instead.
Message text can contain information on temperature or liq-
uid level changes etc.
C r e a t i n g s t a t u s m e s s a g e s
The status messages 1 - 4 are related to analogue input pins
1 - 4.
E.g. if you have connected and wired the analogue input
pin1 to control liquid level, write down the corresponding
information on the first row.
•Key in the desired status message text (7) and the phone
number (9) to which this status message will be sent.
•Additional information (8) can - according to your
choice - include details of some sort but the data field can
be left blank, as well.
Summary of Contents for TRACKBOX 2.1