Smart Hidden Door Lock is a security enabled Z-Wave Plus production, implements Z-Wave Application 
Security Layer in accordance with Z-Wave protocol. The functionality and support command class is difference 
when included as secure or no-secure node. The Door Lock command class and BASIC command class will 
not support while door lock included in no-secure controller. Meanwhile, BASIC command class maps to Door 
Lock Operation command class.

 

2.6 Association 

By using association with SHDL, the SHDL may control another Z-Wave network device with and without 
security transport, e.g. a Dimmer, Relay Switch, Roller Shutter, RGBW Controller, Wall Plug and another 
SHDL. 

NOTE: 

Association allows for direct communication between Z-Wave network devices. Main controller does 

not take part in such communication. Using this mechanism, SHDL may communicate with other devices even 
when the main controller is damaged, e.g. in case of a fire. 

SHDL supports 4 association groups. Each group supports associated 1 devices maximum. 

Association Group 1 is assigned to sending SHDL lifeline status to associated devices, including send Door 
Lock Operation report frame while SHDL unlocked and locked, send Battery level report frame while battery 
level is change. 

Association Group 2 is assigned to sending the Basic Set Off frame to associated device (e.g. another SHDL)  
while the SHDL is unlocked and sending the Basic Set On frame to associated device while the SHDL is 
locked with security transport if SHDL was added to network as security node or with non-security transport if 
SHDL was added to network as non-security  node. 

Association Group 3 is assigned to sending the Basic Set On frame to associated devices with non-security 
transport while the SHDL is unlocked. 

Association Group 4 is assigned to sending the Basic Set Off frame to associated devices with non-security 
transport while the SHDL is locked. 

 

2.8 Z-Wave Function Limited 

Due to SHDL only re-lock automatic while door close and detect by magnetic on the lock, so if Door 
Lock  receives either a Door Lock Operation Set (secure the door) or a Basic Set (0xFF) the command is 
rejected and always fail in Application Reject Command reply and follow with current door lock status report. 

 

2.9 Z-Wave support commands 

 

Generic Deice Type =  GENERIC_TYPE_ENTRY_CONTROL 

 

Specific Device Type =  SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK 

 

Support Command Class = 

 

COMMAND_CLASS_ZWAVEPLUS_INFO, 

 

COMMAND_CLASS_VERSION, 

 

COMMAND_CLASS_MANUFACTURER_SPECIFIC, 

 

COMMAND_CLASS_ASSOCIATION, 

 

COMMAND_CLASS_ASSOCIATION_GRP_INFO, 

 

Summary of Contents for BSL01

Page 1: ...50mA Z Wave frequency 868 4 MHz China Europe 908 4 MHz USA 921 4 MHz Australia New Zealand 869 2 MHz Russia II Z Wave NETWORK This product can be operated in any Z Wave network with other Z Wave certified devices from other manufacturers All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network 2 1 ADD to Network 1 Ensure th...

Page 2: ... state LED state Power on Flicker once Network Inclusion Exclusion Flicker rapidly Inclusion Exclusion Success Glow for 2 seconds Inclusion Exclusion Fail Light off 2 4 Factory default Smart Hidden Door Lock restores factory default automatically when the device is excluded Please use this procedure only when the network primary controller is missing or otherwise inoperable 2 5 Z Wave Plus Securit...

Page 3: ...d and locked send Battery level report frame while battery level is change Association Group 2 is assigned to sending the Basic Set Off frame to associated device e g another SHDL while the SHDL is unlocked and sending the Basic Set On frame to associated device while the SHDL is locked with security transport if SHDL was added to network as security node or with non security transport if SHDL was...

Page 4: ...hown as below As shown on Fig 2 every SHDL has two subset of control system namely as X and Y Each of the subset includes two vary different frequencies for remote controller There are two buttons S1 and S2 which located at bottom left right corner are used to allocate the remote controller to desired system To do that push the any button on the remote controller for 5 seconds in the meanwhile hol...

Page 5: ...or administrator Only XXXX is the 4 to 8 digits default PIN or customized PIN for administrators For administrator only YYYY is the customized 4 to 8 digits access PIN for ordinary users 4 1 Unlock by PIN Decoy PIN is supported with 6 digits of PIN only By entering code as SSSS XXXX YYYY the lock will operate according to respected function with the code combination ...

Page 6: ... 4 3 PIN for users Method 1 On the Key Pad enter SSSS 4 New PIN Max 10 users allowed Method 2 On the Key Pad enter XXXX 1 New PIN Max 10 users allowed 4 4 Deregister A PIN Deregister all administrators PINs enter SSSS 92 Only effecting Admin PINs Deregister all Users PIN M1 enter SSSS 93 M2 enter XXXX 93 Deregister single User s PIN M1 enter SSSS 2 YYYY M2 enter XXXX 2 YYYY 4 5 Adapting A PIN Adap...

Page 7: ...ess K1 mode enter XXXX 61 or SSSS 61 This is the default mode for Single smart card either E card or F card access 4 6 6 The smart card access K2 mode enter XXXX 62 or SSSS 62 A single smart card E or F need to either lock or unlock the SHDL 4 6 7 The smart card access K3 mode enter XXXX 63 or SSSS 63 Double card access mode there are two card Any one of F and E needed at same time to unlock 4 6 8...

Page 8: ...g this period will automatically become the administrator cards There will be only maximum 3 admin cards Once the configuration is successful the buzzer in SHDL will change tone of sound the buzzer will sound once if a card is registered 5 2 E card and F card setting For user After set up the System Card and Admin Card the blue led will be blinking slowly and the card register function in SHDL wil...

Page 9: ...min card 5 times consecutively to deregister all E and F cards the buzzer sounds two long beeps 7 2 Swipe the system card 5 times consecutively to deregister all admin cards no effect on user card and service cards then the buzzer sounds two long beeps VIII Speech function The Benetek Smart Hidden Door Lock SHDL is fully supported by voice reminder The voice reminder support 7 languages include En...

Page 10: ...r five seconds the buzzer sounds 3 beeps with a voice states setup successful in the current system language setup previously Then the Voice Reminder function is activated 8 5 Disable Voice Reminder Hold down for five seconds the buzzer sounds 3 beeps with a voice states setup successful in the current system language setup previously Then the Voice Reminder function is deactivated Please try the ...

Page 11: ...ed 9 2 Fix the base of lock on proper position on the door 9 3 Check the circuit on the lock setup the remote controller and Z wave network put in the 4 AA batteries and tighten the screw on the side of the lock 9 4 Fix the Door Holder according to the position of the latch 9 5 Test all the function on the lock to make sure the installation is carry properly ...