background image

 

 

4. Connecting the automatic valve with the Harmosol 

 
 
 
 

 

 

Figure  4

 

 

 A   earthing 
 B   black 
 C   brown 
 D  Blue or Grey 

 

The Benisol has been cabled beforehand, but this grey cable is not yet connected to the 
three-way-valve. In the picture above, you can find the instructions regarding the 
connections. In this case, the warm water will be sent to the left. By switching the black and 
brown wire, the warm water will be sent to the right. The little black connecting cap is not 
used. The big grey cable connected to the Benisol contains 4 small cables : a grey one, black, 
brown and yellow-green. Please connect them as shown in figure 5. 

 

 

Summary of Contents for BENISOL

Page 1: ...Automated Three Way Valve BENISOL...

Page 2: ...4 2 Temperature sensors of the Harmosol 5 3 Setting the delta temperature and maximum water temperature 6 4 Connecting the automatic valve with the Harmosol 7 5 Connecting the Benisol to a filter pum...

Page 3: ...g manual or contact your dealer Attention Damage caused by not following these introductions is not covered by warranty The J2 H series is suitable for voltages between 85 240V With normal use it s no...

Page 4: ...the connection scheme below As the water enters the valve from the front it is possible to have the solar heating to the left or to the right side of the valve by adjusting the wiring see 4 Connecting...

Page 5: ...teflon insert in the filter outlet When first installing the Benisol the probes will not be attached and should be attached by yourself Please connect the probes as in figure 3 The right temperature...

Page 6: ...low circle Usually a difference of 4 degrees is chosen In the example photograph below when the outer air is more than 4 C warmer than the water the automatic valve or pump will be activated and the w...

Page 7: ...e In the picture above you can find the instructions regarding the connections In this case the warm water will be sent to the left By switching the black and brown wire the warm water will be sent to...

Page 8: ...r heating system via a separate circulation system with pump rather than via an automated valve In this case the black and the grey cables are to be connected to the circulation pump The remaining bro...