27
EN
minv
The opening direction of the motor is selected:
On: Right side motor mount
Off: Left side motor mount (fig.19)
(OFF)
rem
Enables or disables remote radiotransmitters learning, as indicated in the paragraph “Remote
transmitters learning”.
On: Remote learning enabled.
Off: Remote learning not enabled.
(ON)
8.4.3) RADIO (
RADi
)
MENU
FUNZIONE
PP
By selecting this function, the receiver goes in waiting (
Push
) for a transmitter code to assign to the step-step function.
Press the key of the transmitter to assign to this function.
If the code is valid, it is memorised and the message
OK
is displayed
If the code is not valid, the message
Err
is displayed
2Ch
By selecting this function, the receiver goes into waiting (
Push
) for a transmitter code to assign to the second radio channel.
Press the key of the transmitter to assign to this function.
If the code is valid, it is memorised ad the
OK
message is displayed
If the code is not valid, the message
Err
is displayed.
ped
When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the PED function.
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
ntx
By selecting this function the LCD screen shows the number of transmitters memorized into the receiver.
CLR
By selecting this function, the receiver goes into waiting (
Push
) for a transmitter code to erase from the memory.
If the code is valid, it is erased and the message
OK
is displayed
If the code is not valid or not present in memory, the message
Err
is displayed
RTR
Completely erases memory of the receiver. Confirmation of the operation is requested.
By selecting this function the receiver goes into waiting (
Push
) for a new PGM pressure to confirm the operation.
At end of erasing the
OK
message is displayed
8.4.4) CYCLES NUMBER (
Nman
)
Displays the number of complete cycles (open+close) carried out by the automation.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG>
0012
>>> <PG>
3456
: made 123.456 cycles.
8.4.5) MAINTENANCE CYCLES (
maci
)
This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer.
To activate and select the number of manoeuvres, proceed as follows:
Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value).
With the buttons <+> and <-> select one of the numeric values proposed (from OFF to 100). The values are intended as hundreds of cycles of ma-
noeuvres (for example: the value 50 indicates 5000 manoeuvres).
Press the OK button to activate the function. The display will show the message
PROG
.
The maintenance request is indicated to the user by keeping the indicator lamp lit up for other 10 sec after the conclusion of the opening or closing
operation.
8.4.6) RESET (
RES
)
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters
RES
, pressing the <PG> button again resets the control unit. Note: The trans-
mitters are not erased from the receiver nor is the access password and the configuration of synchronism.
All the logics and all the parameters are brought back to default values, it is therefore necessary to repeat the autoset procedure.
8.4.7) AUTOSET (
AUTO
)
This function sets the optimal functioning values of the installation, at the end of the procedure, it sets the average values of torque (PMO/PMC and
PSO/PSC). To carry out the AUTOSET, proceed as follow:
a) Make sure that during the autoset there is no obstacle is in the maneuver area, if necessary, fence off the area so that persons, animals, cars, etc.,
cannot interrupt the procedure.
During the autoset phase, the anti-crushing function is not active, while the activation of inputs and safety devices generates an error.
b) select the function AUTO and press PG.
c) the control unit waits the confirmation to start the procedure “PUSH”
c) press PG to start the AUTOSET procedure.
The control unit performs few maneuvers for the stroke learning and the configuration of the parameters.
In case that the procedure is not successful the message ERR will be shown. Repeat the procedure after checking the wirings and the possible
presence of obstacles.
Summary of Contents for BULL 1524
Page 2: ...2 A B 1 200 245 316 340 300 215 340 34mm BULL PI Optional 40 3 1 8 2 0 4 7 0 1 8 0 2 3 ...
Page 3: ...3 V Z R 4 7 B F T MIN 10 mm MAX 20 mm MIN 120 mm MAX 140 mm 5 6 R D R D ...
Page 5: ...5 12 13 14 C L 7 4 1 2 3 POWER 2 x 1 5 RG 58 5 4 x 0 25 4 6 5 2 x 0 25 3 x 0 25 15 ...
Page 9: ...9 22 DA BT6 ...