background image

21

EN

1) DESCRIPTION

Road barrier for passages up to 8m provided with built in control unit CP.EVA2 and quick external release for manual  maneuver.
It is possible the synchronization of 2 motors for controlling 2 opposed barriers, to do this it is necessary to use the synchronization control unit SIS (optional). 
Wire each other the two control units as shown in figure 14 and configure them as described in the paragraph “Synchronization of two opposed barriers”.
In addition to this it is possible the connection of two backup batteries by 12V  2,1Ah (DA.BT2), as shown in figure 14.
The barrier can work also in absolute absence of power supply by means of the accessory KSUN (sun system composed by solar panel, backup bat-
teries and control unit). 
Every utilization different from the one described in this instruction manual is not allowed and voids the manufacturer warranty.

We would like to remind you that if you register on the site www.beninca.com you will have access to the technical documentation updated for all the 
Benincà products and accessories and the guide for compiling the technical file and documents required under Annex V of the Machinery Directive, 
mandatory under the regulations in force.

IMPORTANT

: whether the barrier is used even for pedestrian passage it is compulsory to carry out the force test as indicated by the European standard 

EN12445 (see the limitations as per the standard EN12453).
In case the passage is for vehicular use only, it is necessary to foresee appropriate signs of pedestrian prohibition.

2) DIMENSIONS

In figure 1 are shown the main dimensions of the EVA.8 barrier.
Overall dimensions are expressed in mm. 
The road barrier length ranges from 7m minimum to 8m maximum.
As about 30cm are required to fix a road barrier, a useful opening of passage, ranging from 6,70m to 7,70m, will be available, as shown in Fig.1
Optional accessories can be fitted onto be barrier (photocells, selector, etc.). For assembly, apply the special covers supplied (Rif. A).

SPECIFICATION

EVA.8

Power supply 
Motor power supply  
Power drawn
Current absorption
Stand by current absorption
Torque
Opening time
Jogging 
Protection class 
Operating temperature
Noise 
Lubrication
Weight

100-250 Vac 50/60Hz

24Vdc
310 W

1,6 A

40 mA (230 Vac - 50 mA (115 Vac)

285 Nm

from 3,5 to 5 sec

Intensive use

IP44

-20°C / +50°C

<70 dB

Agip GR MU EP/2

105kg

3) ARC COMPATIBLE CONTROL UNIT

IMPORTANT, PLEASE READ CAREFULLY:

The radio receiver in this product is compatible with the new ARC (Advanced Rolling Code) transmitters which, thanks to 128-bit encryption
ensure superior copy-security.
Storing new ARC transmitters is quite similar to that of normal rolling code transmitters with HCS coding, but be aware that:
1) ARC transmitters and Rolling Code HCS can not be stored in a single receiver.
2) The first transmitter memorized determines the type of transmitters to be used later. If the first transmitter memorized is ARC, you
can not store Rolling code HCS transmitters, and vice versa.
3) Fixed code transmitters may only be used in conjunction with Rolling code HCS transmitters, bringing the logic CVAR OFF. They
are, therefore, not usable in combination with the ARC transmitters. If the first rolling code transmitter stored is an ARC CVAR the logic
is inoperative.
4) If you want to change the type of transmitters it is necessary to proceed with a receiver reset.

4) OPENING (FIG.2)

The access to the electric and mechanical components of the road barrier is protected by a lock with customized key. Proceed as follows:
1 loosen the two nuts D
2 introduce the key in the lock on the side of the door and turn it anti-clockwise
3 lift the front cover 
4 remove the cover
By removing the front door it is now possible to reach both the control unit, that is placed under the cover, and the mechanical parts of the road barrier.

QUICK PROGRAMMING

- Press the <PG> button, the display goes to the "INST" menu
- Enter the INST menu
- Verify that the parameter BOOM is correct: 3-5 for EVA.5, 7-8 for EVA.8
- Set the barrier position by means of the menu POS, by default the barrier is set as RIGHT BARRIER
- Enter the menu AUTO, confirm with <PG> and wait until the barrier has carried out the autoset of the parameters
- By means of the menus PAR and LOG, select the parameters and the logic functions wanted according to the type of installation in object

IMPORTANT

:

 After every change of the parameters FSTS. SLDO, SLDC, TSMO, TSMC, the barrier executes an opening maneuver followed by a 

closing one in order to acquire the new values of current and torque, on the screen will appear  the message <PRG> 

Summary of Contents for EVA.8

Page 1: ...L8543159 03 2017 rev 5 EVA 8 UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI IT EN DE FR ES PL...

Page 2: ...2 D A A C B B D EVA 8 SX EVA 8 DX 1 2 3 375 300 260 460 1265 Min 4 70m Max 6 70m min 6 70m max 7 70m...

Page 3: ...3 L L EVA8 LEFT EVA8 RIGHT STANDARD A B D1 R D2 A V 4 CLAC CLACK 5...

Page 4: ...oning VE P650 optional Montage der Fundamentplatte VE P650 option Mise en place de la plaque de fondation VE P650 optionnel Posicionamiento de la placa de alimentaci n VE P650 opcional U o enie p yty...

Page 5: ...5 D T 8 O C O C SWC Slow down Close SLDC Slow down Open SLDo 9 10...

Page 6: ...6 F2 F1 V2 V1 11 3 1 2 8 4 5 6 7 2 9x16 FTC S A Line 3x1 5mm B Photo TX 2x0 5mm C Photo RX 4x0 5mm D EVA Led 2x0 5mm E SC EN 2x0 5mm A B C D E 12...

Page 7: ...TITUZIONE MOLLA SPRING REPLACEMENT FR HLING ERSATZ REMPLACEMENT DES RESSORTS REEMPLAZO DEL RESORTE WYMIANA SPR YNY ASSEMBLAGGIO ASTA 8M 8M ROD ASSEMBLY 8M STAB MONTAGE TIGE ARTICUL E 8M MONTAJE DE LA...

Page 8: ...LD ANT CLOSE P P U5 F1 MOT AUX 24V BLINK AUX2 COM SWO SWC STOP PHOT OPEN SHLD ANT CLOSE P P MOT AUX ANT M LAMP 24Vdc 24Vdc 500 mA CP EVA2 BAR LIGHT 24Vdc L LED 1 LED 2 F1 N SA 24V 100 250 Vac 2xDA BT2...

Page 9: ...4Vac 24Vac COM NC NO RX TX 24Vdc COM AUX1 PHOT 24Vdc AUX1 AUX1 0004 tst1 on SCA PHOTOTEST AUX1 0000 AUX1 0003 24Vdc AUX1 SERVICE LIGHT L N 230Vac LAMP 24Vac LAMP Rel 24Vdc MASTER Menu BUS ID 0 SLAVE M...

Page 10: ...5 ok 7 8 0 0 ok ok ok PRG PRG PRG PRG PRG PRG PRG PRG PRG PRG PRG PRG PRG PRG PRG PRG P P 0 P P P tca fsts sldo sldc tsmo pmo pmc pso psc seav sear 20 99 50 50 20 tsmc 20 20 20 20 0 0 TLS 60 saso 0 s...

Page 11: ...cisk PG Premere simultaneamente e Press simultaneously keys and Gleichzeitig und dr cken Presser simultan ment et Presionar simult neamente y Naciska jednocze nie i Selezionare il valore desiderato co...

Page 12: ...t unless under the supervision of or following training by persons responsible for their safety Apply all safety devices photocells safety edges etc required to keep the area free of impact crushing d...

Page 13: ...cation Weight 100 250 Vac 50 60Hz 24Vdc 310 W 1 6 A 40 mA 230 Vac 50 mA 115 Vac 285 Nm from 3 5 to 5 sec Intensive use IP44 20 C 50 C 70 dB Agip GR MU EP 2 105kg 3 ARC COMPATIBLE CONTROL UNIT IMPORTAN...

Page 14: ...he special shape of the slots on the bottom of the barrier cabinet allow to adjust finely the position of the barrier It is suggested to leave 30 mm of threaded bar out from the foundation plate a big...

Page 15: ...unit is carried out using the LCD display on the control unit and setting the desired values in the programming menus described below The parameters menu allows you to assign a numerical value to a fu...

Page 16: ...seful for facilitat ing the manual release 0 5 0 sasc Sets a short reversion after reaching the limit switch in close position Can be useful for facilitat ing the manual release 0 5 0 aux1 Selects the...

Page 17: ...graph Remote transmitters learning On Remote learning enabled Off Remote learning not enabled OFF 13 3 4 RADIO RADI MENU FUNZIONE PP By selecting this function the receiver goes in waiting Push for a...

Page 18: ...minutes in order to allow adjustments and tests on functions By replacing the 0000 code with any other code the protection of the control unit is enabled thus preventing the access to any other menu I...

Page 19: ...Some messages that are displayed in case of function anomalies are listed as follows Err Generic error Error inserting password or memorizing transmitter Err1 Motor error Verify the motor wirings faul...

Page 20: ...ion of the emergency manual release It is mandatory not to carry out extraordinary maintenance or repairs as accidents may be caused These operations must be carried out by qualified personnel only Th...

Page 21: ...9686441 5 5230003 6 9686443 7 9686444 8 9688204 9 9688205 10 9686117 11 9686115 12 9686473 13 9686160 14 9686438 15 9686120 16 5780006 17 9686517 1 pz 480mm 18 9576001 1 pz 364mm 19 F8262103 20 96882...

Page 22: ...69 Ref EVA8 Code Note 1 9686556 2 9686112 3 9686111 4 9686107 5 9686109 6 9686555 7 9688211 1 6 7 3 2 4 5...

Page 23: ...ato di Conformit pi completo e recente disponibile consultando il sito www beninca com oppure pu essere richiesto presso Automatismi Beninc S p A Sandrigo VI Italy UE Declaration of Conformity DoC Man...

Reviews: