14
15
• Close the gate until it touches the stopper.
• Loosen the tting screw of the cam and adjust the cam until triggering of the micro-switch.
• The same operation should be carried out with the other cam, with completely open gate.
• Reset the automatic operation and check the correct positioning of the cams by opening and closing the
gate for a few times.
• Tighten the xing screws of the cams.
Note:
The PREMIER /R/L (230Vac) models feature a thrust of some seconds on the stoppers without damaging
the gear motor. If required, it is therefore possible to select the timed operation, thus excluding the limit
switches.
In the PREMIER 24 model, cams should be adjusted and limit switches should be connected to the control
unit.
Release by hand
As regards the manual operation, should a power failure occur two solutions are available for the PREMIER
unit :
Release from inside (Fig. 3)
• Insert the customised key C, and turn it clockwise.
• Turn the release lever L for at least 90° clockwise.
• At this point, the reduction gear is released and the gate can be moved by had.
• To reset the normal operation, move the lever L to the original position and turn key C anti-clockwise. When
the unit is powered again, the normal operating mode will be reset with the rst movement of the gate.
Internal-external release with cord (Item DU.MS45) (Fig. 4 - optional)
• Insert the steel cable C on lever L.
• Introduce the sheath G with the cable gland K until it reaches the hole F.
• Fit the steel cable C in the handle, according to Fig. 4.
• Turn the handle to release.
• By turning the handle again, the rst operation will reset the normal operating mode.
Applications
Application suitable to max 90° opening inward (g. 5.
Application suitable to max 130° opening (g. 6).
P.N. When opening it’s necessary that the arm has at least the signaled space.
Application suitable to opening to the outside (gg. 7 - 8).
CAUTION
The civil liability policy, which covers possible injuries to people or accidents caused by defects in construc-
tion, requires the system to be to existing standard and to use original Benincà accessories.