WARNING

GENERAL INFORMATIONS

The product shall not be used for purposes or in ways other than those for which the product is intended for and as described 
in this manual. Incorrect uses can damage the product and cause injuries and damages.
The company shall not be deemed responsible for the non-compliance with a good manufacture technique of gates as well 
as for any deformation, which might occur during use. Keep this manual for further use. 

INSTALLER GUIDE

This manual has been especially written to be use by qualified fitters. Installation must be carried out by qualified personnel 
(professional installer, according to EN 12635), in compliance with Good Practice and current code. 
Make sure that the structure of the gate is suitable for automation. 
The installer must supply all information on the automatic, manual and emergency operation of the automatic system and 
supply the end user with instructions for use.

GENERAL WARNINGS

Packaging must be kept out of reach of children, as it can be hazardous. For disposal, packaging must be divided the various 
types of waste (e.g. carton board, polystyrene) in compliance with regulations in force. 
Do not allow children to play with the fixed control devices of the product. 
Keep the remote controls out of reach of children. This product is not to be used by persons (including children) with reduced 
physical, sensory or mental capacity, or who are unfamiliar with such equipment, unless under the supervision of or following 
training by persons responsible for their safety. 
Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and 
shearing hazard. 
Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the 
operating logic of the system and forces generated by the automated system. Installation must be carried out using safety 
devices and controls that meet standards EN 12978 and EN 12453. 
Only use original accessories and spare parts, use of non-original spare parts will cause the warranty planned to cover the 
products to become null and void. All the mechanical and electrical parts composing automation must meet the requirements 
of the standards in force and outlined by CE marking.

ELECTRICAL SAFETY

The box containing the control unit is secured to barrier case with two screws to avoid damage during transport. Once the 
barrier has been positioned it possible to remove the screws and to unhook the box from the case so as to facilitate wiring 
operations and the preparation of the control unit. On completing installation, secure the box to the barrier case again.
An omnipolar switch/section switch with remote contact opening equal to, or higher than 3mm must be provided on the 
power supply mains.
Make sure that before wiring an adequate differential switch and an overcurrent protection is provided.
Pursuant to safety regulations in force, some types of installation require that the gate connection be earthed. During instal-
lation, maintenance and repair, cut off power supply before accessing to live parts. 
Also disconnect buffer batteries, if any are connected. The electrical installation and the operating logic must comply with 
the regulations in force. The leads fed with different voltages must be physically separate, or they must be suitably insulated 
with additional insulation of at least 1 mm. The leads must be secured with an additional fixture near the terminals.
During installation, maintenance and repair, interrupt the power supply before opening the lid to access the electrical parts
Check all the connections again before switching on the power. The unused N.C. inputs must be bridged.
Consult the control unit instructions manual as regards the regulation of the operating times and logic, the connection of the 
accessories and of the safety devices, etc.

WASTE DISPOSAL

As indicated by the symbol shown, it is forbidden to dispose this product as normal urban waste as some parts might be 
harmful for environment and human health, if they are disposed of incorrectly. 
Therefore, the device should be disposed in special collection platforms or given back to the reseller if a new and similar 
device is purchased. 
An incorrect disposal of the device  will result in fines applied to the user, as provided for by regulations in force.

Descriptions and figures in this manual are not binding. While leaving the essential characteristics of the product unchanged, the manufacturer reserves 
the right to modify the same under the technical, design or commercial point of view without necessarily update this manual.

QUICK PROGRAMMING

- Press the <PG> button, the display goes to the "INST" menu
- Enter the INST menu
- Verify that the parameter BOOM is correct: 7-8  for all VE.650 models (factory settings).
- Set the barrier position by means of the menu POS, by default the barrier is set as RIGHT BARRIER
- Enter the menu AUTO, confirm with <PG> and wait until the barrier has carried out the autoset of the parameters
- By means of the menus PAR and LOG, select the parameters and the logic functions wanted according to the type of installation 
in object

IMPORTANT

:

 After every change of the parameters FSTS. SLDO, SLDC, TSMO, TSMC, the barrier executes an opening maneuver 

followed by a closing one in order to acquire the new values of current and torque, on the screen will appear  the message <PRG> 

Summary of Contents for VE.650

Page 1: ...L854200192 07 2020 rev 1 VE 650 UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI IT EN DE FR ES PL...

Page 2: ...3 1 M a x 6 5 0 m 35 300 1080 225 4 5 0 M a x 6 2 0 m A 460 170 255 310 F F A B C VE P650 OPTIONAL E D 2 3 P A C V...

Page 3: ...4 6 V T M D L 4 5 STANDARD...

Page 4: ...al stop for closing Mech Halt Schlie ung Arr t m canique fermeture Tope mec nico cierre Mechanizm zatrzymuj cy zamykanie D Dado tensionamento molla Spring tensioning nut Federspannmutter crou de mise...

Page 5: ...i na zwalnianie i zamnkni cia O Camma finecorsa apertura Opening limit stop cam Endschalternocken ffnen Came fin de course d ouverture Leva fin de carrera de apertura Krzywka kra c wki otwarcia Fineco...

Page 6: ...zelle vom Empf nger 4 Blinker VE L650 5 Pufferbatterien 2 Stck 12V 6 serienweise angeschlossen 6 Selektor 7 Druckregler SC PP 8 Pneum Anschlag SC P35 9 Grundplatte f r Batterien zusammen mit der Steue...

Page 7: ...RG PRG PRG PRG tca fsts sldo sldc tsmo pmo pmc pso psc seav sear 20 99 50 50 20 tsmc 20 20 20 20 0 0 TLS 60 saso 0 sasc 0 0 AUX1 PRG 2 AUX2 20 LOG RADI TCA tca IBL IBCA SCL PP PRE htr ltca tst1 tstm c...

Page 8: ...Die Taste PG dr cken Appuyez sur la touche PG Presionar la tecla PG Wcisn przycisk PG Premere simultaneamente e Press simultaneously keys and Gleichzeitig und dr cken Presser simultan ment et Presiona...

Page 9: ...ANT CLOSE P P U5 F3 MOT AUX 24V BLINK AUX2 COM SWO SWC STOP PHOT OPEN SHLD ANT CLOSE P P MOT AUX ANT M LAMP 24Vdc 24Vdc 500 mA CP LADY BAR LIGHT 24Vdc L LED 1 LED 2 F1 N SA 24V 100 250 Vac 2xDA BT2 Op...

Page 10: ...24Vac 24Vac COM NC NO RX TX 24Vdc COM AUX1 PHOT 24Vdc AUX1 AUX1 0004 tst1 on SCA PHOTOTEST AUX1 0000 AUX1 0003 24Vdc AUX1 SERVICE LIGHT L N 230Vac LAMP 24Vac LAMP Rel 24Vdc MASTER Menu BUS ID 0 SLAVE...

Page 11: ...ompleting installation secure the box to the barrier case again An omnipolar switch section switch with remote contact opening equal to or higher than 3mm must be provided on the power supply mains Ma...

Page 12: ...to that of normal rolling code transmitters with HCS coding but be aware that 1 ARC transmitters and Rolling Code HCS can not be stored in a single receiver 2 The first transmitter memorized determine...

Page 13: ...he unlocking lever is found inside the barrier column Lower the lever to release the shaft Bring the lever back to its original position to reset automatic movement of the shaft 10 MECHANICAL STOPS AD...

Page 14: ...o the function 7 Press the button PG the display shows the signal PRG which indicates that programming has been completed 13 2 PROGRAMMING NOTES Simultaneously pressing and from inside a function menu...

Page 15: ...ean contact 0 Open barrier light close contact when the barrier is open open contact when the barrier is close intermittent during the maneuver fig 11 SCA 1 Second radio cannel of the built in receive...

Page 16: ...ivated only with connected and operating emergency batteries On Activated function In the event of power failure the control unit causes an opening operation The barrier remains open until the power s...

Page 17: ...e typed in by using the numbers from 0 to 9 and the letters A B C D E F The default value is 0000 four zeros and shows the absence of a protection code While typing in the code this operation can be c...

Page 18: ...F3 CP LADY T1A Fuse for the protection of the accessories power supply F1 SA 24V T4A Fuse for general protection 18 BACK UP BATTERIES The control unit CP LADY includes the power pack SA 24V predispose...

Page 19: ...rection until it is blocked Maintenance Every month check the good operation of the emergency manual release It is mandatory not to carry out extraordinary maintenance or repairs as accidents may be c...

Page 20: ...62 7 2 3 4 5 6 1 Ref Code Note 1 9686556 2 968601519 3 96861520 4 9686107 5 9686109 6 7 968601521...

Page 21: ...15 15 I 13 14 11 12 16 16 I 17 18 19 Ref Code Note 9 9686120 10 9686160 11 9686116 12 9686118 13 9686115 14 9686117 15 9686114 15 I 9686318 16 9686113 16 I 9686316 17 9686119 18 9686666 19 968601410...

Page 22: ...AUTOMATISMI BENINC SpA Via Capitello 45 36066 Sandrigo VI Tel 0444 751030 r a Fax 0444 759728...

Reviews:

Related manuals for VE.650