background image

Summary of Contents for FS140

Page 1: ...ase read the warranty and return the warranty card to initiate coverage We Strongly Recommend The Use Of A Carbon Monoxide Detector When Using Any Product That Consumes Fossil Fuels It is the responsibility of the person or company installingthis furnace to verify before the installation that the furnace certificationsshown on this page meet or exceed all local state and regulatoryrequirements for...

Page 2: ...nother type of fuel Connect the furnace to an approved solid fuel factory built chimney in CANADA CAN ULC S629 standard for 650 chimney in the UNITED STATES UL103 Chimneys for Residential Type and Building Heating Appliances Factory Built or a safe clean sound condition masonry chimney equipped with an approved liner in CANADA CAN ULC S635 M90 Standard for LiningSystems for existingmasonryor Facto...

Page 3: ... 8 Furnace location and duct work installation must conform to installation clearances shown on the front of the furnace also see the reprint in this manual on page 3 Place the furnace on a non combustible floor Locate the furnace as close to the chimneyas possible 9 The fuel supply tank and fuel lines should be installed in accordance with codes and standards having jurisdiction in your area 10 T...

Page 4: ...lenum and first 6 of duct 6 then 2 Return Air Plenum and first 6 of duct 3 then 1 CAUTION Ensure a MINIMUM of 200 Sq In of return air back to the Furnace ADJUSTMENTS OF DAMPER MOTOR AND CHAIN The damper chain should be adjusted when the damper door is in the down position In this position the chain should be adjusted so there is a small amount of slack The amount of lift or opening of the damper d...

Page 5: ...ervice technician INSTRUCTIONS WOOD SECTION DO NOT connect this unit to an automatic stoker or sawdust burner Keep the furnace smoke pipes and chimneyclean It will increase efficiency and reduce the risk of soot and creosote fires When usinguncured wood clean and inspect the furnace smoke pipes and chimney monthly or as necessary to prevent soot and creosote build up Solid fuel requires a sufficie...

Page 6: ...CA UTION UseNo 2furnace oil only DO NOT USE GASOLINE CRANKCASE OIL OR ANY OIL CONTAINING GASOLINE DO NOT press the reset button on the burner relay more than twice Then call a qualified service technician Keep the valve shut off if the oil burner is shut down for an extended period of time DO NOT ATTEMPT TO START THE BURNER WHEN EXCESS OIL HAS ACCUMULATED WHEN THE FURNACE IS FULL OF VAPOR OR WHEN ...

Page 7: ...he burner by following the instructions under paragraph TO START THE BURNER 6 It is recommended that a qualified servicetechnicianbe called to clean the unit and burner and make sure that the burner isoperating properly The installer should identify the emergencyshut offswitch and valves WHEN THE BURNER IS IN OPERATION 1 Check flame periodically if it becomes out of shape or smoky call a qualified...

Page 8: ...e technician The blocked flue sensor is designed to shut off the burner and close the damper door in the event that the flue has become blocked When this has happened the burner cannot be started again and the damper door will not open until the sensor has been reset Pushing in the red button which is accessed through the hole in the front of the sensor resets the sensor CAUTION Only try this once...

Page 9: ... WMO 1 Oil Thermostat b blue y yellow wb white with black wy white with yellow Line Neutral S GroundJ Warning Do Not Place Wire On x Damper Motor Thermostat 24 Volt 60 Hz Line In 120 VAC 00 Blower Motor 120VAC 24VAC Transformer All 120Volt 60Hz Wire Must Be 16 AWG TEW 90 C Encased In CSA Certified 3 8 Flexible Metal Conduit ...

Page 10: ...er Blocked Flue Sensor Field Controls WMO Oil Thermostat Cad Ce LveHow G Wood Damper Motor Thermostat 120VAC 24VAC Transformer Burner Motor 120 Volt 60 Hz 24 Volt 60 Hz Line Neutral Ground Line In 120 VAC Blower Motor All 120 Volt 60Hz Wire Must Be 16 AWG TEW90 C Encased In CSA Certified 3 8 Flexible Metal Conduit Using Anti Shorts In CableEnds ...

Page 11: ...white with black wy white with yellow Blocked Flue Sensor Field Controls WMO 1 120VAC 24VAC Transformer 120 Volt 60 Hz 24 Volt 60 Hz Line Neutral Ground Line In 120 VAC Blower Motor All 120 Volt 60Hz Wire Must Be 16 AWG TEW90 C Encased In CSA Certified 3 8 Flexible Metal Conduit Using Anti Shorts In Cable Ends ...

Page 12: ...e two support straps through the openings provided in the ash baffle Replace the two stainless steel cotter pins and spread the two legs to prevent falling out CAUTION DO NOT START A FIRE WITH THE ASH BAFFLE REMOVED Sight Port Door Gasket orderf FS105K Sight Port Door order FS101 Oil Doory Casket order FS107 I 1 Stainless Steel Support Straps order FS138 D 2 Stainless Steel Cotter Pins order FS139...

Page 13: ...the wood fire door This will expose the three clean out covers 4 Remove the three brass nuts located in the center ofeach clean out cover Usecare in removing covers to prevent damage to the gaskets Thoroughly clean out the exposed tubes It is necessary to remove the smoke pipe to clean the back cross over tube These tubes should be checkedweeklyuntila proper cleaning cycle is established After cle...

Page 14: ...r motor allowing air into the firebox Resulting in a hotter fire The fan control senses heat in the supply plenum And activates the blower motor forcing warm air through the supply ducts The damper motor to close the combustion air damper Resulting in a low fire The fan control senses low temperature in the supply plenum And shuts off the blower motor 13 ...

Reviews: