10/ 2004
BENNING MM 5
14
Measuring
range
Resolution
Measurement accuracy
Max.
meas. current Max. no-load voltage
1 mV ± (1.5 % of r 5 digits)
1.5 mA
3,0 V
7.7 Frequency range (set with rotating switch)
Overload protection for frequency measurements: 600 V
eff
Measuring
range
Resolution
Measurement accuracy
for 5 V
eff
max.
Min. input
frequency
Min. sensitivity
3 kHz
1 Hz
± (0.01 % of r 1 digit)
20 Hz
100 mV
eff
30 kHz
10 Hz
± (0.01 % of r 1 digit)
200 Hz
100 mV
eff
300 kHz
100 Hz
± (0.01 % of r 1 digit)
2 kHz
100 mV
eff
3 MHz
1 kHz
± (0.01 % of r 1 digit)
20 kHz
100 mV
eff
30 MHz
10 kHz
± (0.01 % of r 1 digit)
200 kHz
250 mV
eff
7.8 Frequency display (when ~Hz button pressed)
AC V Measuring range
Measurement accuracy
Minimum sensitivity
300 mV
± (0.01 % of r 5 digits)
3 mV
eff
3 V
± (0.01 % of r 5 digits)
30 mV
eff
30 V
± (0.01 % of r 5 digits)
0,3 V
eff
300 V
± (0.01 % of r 5 digits)
3 V
eff
750 V
± (0.01 % of r 5 digits)
30 V
eff
AC V Measuring range
Measurement accuracy
Minimum sensitivity
30 mA
± (0.01 % of r 5 digits)
0,3 mA
eff
300 mA
± (0.01 % of r 5 digits)
3 mA
eff
10 A
± (0.01 % of r 5 digits)
0,1 A
eff
8. Measuring with the BENNING MM 5
8.1 Preparation for measurement
Store and use the BENNING MM 5 only under the correct temperature
conditions stated. Always avoid longer exposure to sunlight.
- Check the rated voltage and rated current stated on the safety test leads.
The safety test leads supplied with the unit are suitable for the rated voltage
and current of the BENNING MM 5.
- Check the insulation of the safety test leads. If the insulation is damaged in
any way, do not use the leads.
- Check the continuity of the safety test leads. If the conductor in the safety
test lead is interrupted, do not use the leads.
- Before selecting another function with the rotating switch
, always
disconnect the safety test leads from the measuring point.
- Sources of strong current in the vicinity of the BENNING MM 5 may cause
unstable or incorrect readings.
8.2 Voltage and current measurement
Always observe the maximum voltage to earth potential!
Electrical hazard!
The maximum voltage which may be applied to the sockets
- COM- socket
- socket for V, Ω, Hz
- socket for mA range
and the
- socket for 10 A range
of the BENNING MM 5 to earth is 1000 V.