1.4 Guidelines for Safe Handling and Installation 

    
IMPORTANT

IMPORTANT

IMPORTANT

IMPORTANT

    

THIS PRODUCT IS DESI

THIS PRODUCT IS DESI

THIS PRODUCT IS DESI

THIS PRODUCT IS DESIGNED FOR INSTALLATIO

GNED FOR INSTALLATIO

GNED FOR INSTALLATIO

GNED FOR INSTALLATION BY QUALIFIED PERSO

N BY QUALIFIED PERSO

N BY QUALIFIED PERSO

N BY QUALIFIED PERSONNEL ONLY.

NNEL ONLY.

NNEL ONLY.

NNEL ONLY.    

    
ALL HANDLING AND INS

ALL HANDLING AND INS

ALL HANDLING AND INS

ALL HANDLING AND INSTALLATIONS MUST BE P

TALLATIONS MUST BE P

TALLATIONS MUST BE P

TALLATIONS MUST BE PERFORMED IN COMPLIAN

ERFORMED IN COMPLIAN

ERFORMED IN COMPLIAN

ERFORMED IN COMPLIANCE WITH 

CE WITH 

CE WITH 

CE WITH 

ALL APPLICABLE CODES

ALL APPLICABLE CODES

ALL APPLICABLE CODES

ALL APPLICABLE CODES,,,, RULES AND REGULATIO

 RULES AND REGULATIO

 RULES AND REGULATIO

 RULES AND REGULATIONS.

NS.

NS.

NS.    

 
In addition to the applicable rules and regulations, please follow all guidelines for safe handling 
and/or installation of BenQ Solar modules. As always observe industry best practices when 
handling  and/or  installing  any  BenQ  Solar  module.  Save  this  Installation  Guide  for  future 
reference. 
 
LIFTI

LIFTI

LIFTI

LIFTING AND HANDLING

NG AND HANDLING

NG AND HANDLING

NG AND HANDLING    

 

Do not lift the module or carry module by junction box or PV cables.   

 

Do not drill holes in the frame. This will void warranty and may affect frame strength. 

 

Avoid scratching the frame. Scratches to the frame will compromise protective coating 

and can result in corrosion or weakened structure. 

 

Do not scratch or damage the module backsheet. Scrathes to the backsheet could affect 

module performance. 

 

Do not stand on, drop, scratch or allow objects to hit modules (especially module glass). 

 

O not install or handle the modules when wet or during periods of high wind. 

 

Do not install the modules where there may be flammable gases or vapors, since sparks 

may be produced. 

 

When  storing  the  modules,  take  steps  to  cover the  DC  connectors  and  prevent  dust 

from collecting on or in the connectors. 

    

ELECTRICAL HANDLING AND INSTALLATION

ELECTRICAL HANDLING AND INSTALLATION

ELECTRICAL HANDLING AND INSTALLATION

ELECTRICAL HANDLING AND INSTALLATION    

 

The  module’s  DC  connection  points  conduct  direct  current  (DC)  and  are  sources  of 

voltage when the module s under load and any time it is exposed to light. 

 

Direct current can arc across gaps and may cause injury or death if improper connection 

or disconnection is made, or if contact is made with module leads that are frayed, torn 

or otherwise damaged. 

 

Summary of Contents for Back contact 96 cells Series

Page 1: ...s 60 cells series 60 cells series PM250M01 PM250M01 PM250M01 PM250M01 PM060M02 PM060M02 PM060M02 PM060M02 Mo Mo Mo Mono no no no 60 cells with light weight series 60 cells with light weight series 60...

Page 2: ...1 Series 8 2 7 PM072P00 Series 8 2 8 PM060P00 Series 9 2 9 PM096B00 Series 9 Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines 10...

Page 3: ...Certifications See BenQ Solar Limited Warranty document for full product warranty details and limitations Product Warranty version is based on warranty note in effect at the time of product manufactur...

Page 4: ...I LIFTING AND HANDLING NG AND HANDLING NG AND HANDLING NG AND HANDLING Do not lift the module or carry module by junction box or PV cables Do not drill holes in the frame This will void warranty and m...

Page 5: ...in order to prevent untrained persons from disconnecting the modules once installed There are no serviceable parts within the module Do not attempt to change or repair any part of the module Damaged m...

Page 6: ...ing the modules do not allow the anodized profiles frames to come into contact with contaminants such as cement or mortar which will cause damage to the anodic oxide coatings A A A Always contact your...

Page 7: ...ductor capacities fuse sizes and size of controls connected to PV output An additional 1 25 multiplier may be required by the NEC for sizing fuses and conductors as described in the NEC section 690 8...

Page 8: ...Weight Module Weight Module Weight 18 5 kg 41 1 lbs Power 240W 245W 250W 255W 260W Efficiency 14 9 15 2 15 5 15 8 16 1 Vmp V 29 9 30 3 30 6 30 8 31 2 Imp A 8 03 8 09 8 17 8 28 8 34 Voc V 37 0 37 2 37...

Page 9: ...L x W x H s L x W x H s L x W x H 1639 x 983 x 35 mm 64 52 x 38 7 x 1 38 in Module Weight Module Weight Module Weight Module Weight 10 5 kg 23 3 lbs Power 265W 270W 275W 280W 285W 290W Efficiency 16...

Page 10: ...39 8 44 Voc V 37 4 37 7 37 7 37 9 38 1 Isc A 8 69 8 76 8 83 8 87 8 93 Maximum Tolerance of Power 0 3 2 9 PM096B00 Series Module Dimensions L x W x H Module Dimensions L x W x H Module Dimensions L x...

Page 11: ...AND OR PRODUCT WARR AND OR PRODUCT WARR AND OR PRODUCT WARRANTY ANTY ANTY ANTY 3 1 Mounting with Screws Secure the module to the structure using only the factory drilled mounting holes Do not drill an...

Page 12: ...idistant from the closest module frame corner see Figure 1 Ensure the clamps are of sufficient design strength to allow for the maximum design pressure of the module Measurements of D1 D2 D3 and D4 be...

Page 13: ...12 Figure Figure Figure Figure 2 2 2 2 Long rail mounting clamp zone D1 and D2 Figure Figure Figure Figure 3 3 3 3 Short rail mounting clamp zone D3 and D4...

Page 14: ...298 mm 298 mm 11 73 in 11 73 in 11 73 in 11 73 in PM250M01 PM250M01 PM250M01 PM250M01 228 228 228 228 mm mm mm mm 8 98 8 98 8 98 8 98 in in in in 428 428 428 428 mm mm mm mm 16 85 16 85 16 85 16 85 in...

Page 15: ...cation Details Module Clamp Location Details Module Clamp Location Details Module Clamp Location Details Long rail Long rail Long rail Long rail clamping for 5400 Pa design strength clamp between D1 D...

Page 16: ...ing radius of r 4x static steady r 5x dynamic cable diameter must be maintained The cable must be routed in a way that tensile stress on the conductor or connection s is avoided Figure Figure Figure F...

Page 17: ...f the nominal voltage BenQ Solar PV modules are supplied with or without cables according to where they are ordered If supplied without cables it is recommended that cables with cross sections between...

Page 18: ...nd contact The grounding screw and bolt are usually sold separately from the mounting equipment Please make sure the grounding screw breaks the anodized surface of the module frame around the holes An...

Page 19: ...ugh use of clamps that penetrate the anodization in conjunction with grounding of the mounting system or through direct grounding of the frames by attaching a copper wire to a grounding hole of each m...

Page 20: ...odules guarantees their insulation up to a DC voltage of The IEC 61730 certificate of these modules guarantees their insulation up to a DC voltage of The IEC 61730 certificate of these modules guarant...

Page 21: ...odule configurations for 1000V inverter Maximum series 1000V Product Voc 1 25 safety factor Example The Voc of PM200M00_200 is 30 4V then the maximum series parallel module configurations for 1000V in...

Page 22: ...roppings collecting on the module surface Thin layers of dust normal soiling that reduce the sun s intensity evenly are not dangerous and the power reduction is not as significant as other debris Clea...

Page 23: ...anodic oxide coatings is generally every six months When cleaning be sure not to damage or scratch this coating Dirt on the frame can generally be cleaned off using warm mildly soapy water and a fiber...

Page 24: ...duct meets or exceeds the requirements set forth by UL1703 for PV Modules This UL1703 Standard covers flat plate PV modules intended for installation on buildings and those intended to be freestanding...