Fig. 3
Fig. 4
8.
The on screen display shows the “Meshut 26” message (Fig. 5). Put the camera in front of the light
source box adjust the LV value to LV 12 according to the instruction.
9.
Tap “OK” button and then press “Set” button. Calibration program will execute automatically.
10.
When the on-screen display shows “OK” (Fig. 6), it means the test is passed. If it shows “NG”, it means
the test was failed.
11.
The on screen display shows the “Meshut 80” message (Fig. 7). Put the camera in front of the light
source box and adjust the LV value to LV 14 according to the instruction.
12.
Tap “OK” button and then press “Set” button. Calibration program will execute automatically.
13.
When the on-screen display shows “OK” (Fig. 8), it means the test is passed. If it shows “NG”, it means
the test was failed.
14.
The on screen display shows the “INF Focus ” (Fig. 9). It requires to use collimator to calibrate. Put the
camera in front of collimator.
15.
Tap “OK” button and then press “Set” button. Calibration program will execute automatically.
16.
When the on-screen display shows “OK” (Fig. 10), it means the test is passed. If it shows “NG”, it means
the test was failed.