Maintenance
64
11. Restart the projector.
Do not turn the power on with the lamp cover removed.
Resetting the lamp timer
12. After the startup logo, open the On-Screen
Display (OSD) menu. Go to the
SYSTEM
SETUP: Advanced
>
Lamp Settings
menu. Press
MODE/ENTER
. The
Lamp
Settings
page displays. Press to highlight
Reset lamp timer
and press
MODE/
ENTER
. A warning message displays asking if you want to reset the lamp timer.
Highlight
Reset
and press
MODE/ENTER
. The lamp time will be reset to '0'.
Do not reset if the lamp is not new or replaced as this could cause damage.
7.
Tighten the screws that secure the
lamp.
•
Loose screw may cause a bad connection,
which could result in malfunction.
•
Do not over tighten the screws.
8.
Ensure the handle is fully laid flat and
locked in place.
9.
Replace the lamp cover by sliding it
into place.
10. Tighten the screw that secures the
lamp cover.
•
Loose screw may cause a bad connection,
which could result in malfunction.
•
Do not over tighten the screw.
(a)
(b)