Secure each module to the structure using four stainless steel bolts, with nuts, washers, and 

lock washers. When using this mounting option, only the existing mounting holes (with the 

current diameter of 9mm

9mm

9mm

9mm) can be used for module to meet 5400Pa design strength under UL 

1703. 

    

PM

PM

PM

PM060M01

060M01

060M01

060M01    

Secure each module to the structure using four stainless steel bolts, with nuts, washers, and 

lock  washers.  Only  the  existing  mounting  holes  (Diameter:  6.

6.

6.

6.6

66

6mm

mm

mm

mm)  that  can  be  used  for 

module to meet 3600Pa design strength under IEC 61215/ IEC 61730 and to meet 2400Pa 

design strength under UL 1703.

   

 

PM

PM

PM

PM072

072

072

072P

P

P

PW

W

W

W0

00

0 / PM072MW0

 / PM072MW0

 / PM072MW0

 / PM072MW0    

Secure each module to the structure using four stainless steel bolts, with nuts, washers, and 

lock washers. When using this mounting option, only the existing mounting holes (with the 

current diameter of 8

88

8mm

mm

mm

mm) can be used for module to meet 5400Pa design strength under UL 

1703. 

 

PM

PM

PM

PM072

072

072

072P

P

P

PW

W

W

WA

A

A

A    

Secure each module to the structure using four stainless steel bolts, with nuts, washers, and 

lock washers. When using this mounting option, only the existing mounting holes (with the 

current diameter of 8mm

8mm

8mm

8mm) can be used for module to meet 5400Pa design strength under IEC 

61215/ IEC 61730. 

 

PM096B00

PM096B00

PM096B00

PM096B00    

Secure  each  module  to  the  structure  using  four  M6  (¼”)

M6  (¼”)

M6  (¼”)

M6  (¼”)  stainless  steel  bolts,  with  nuts, 

washers, and lock washers per module. Only the mounting holes that are 322mm (12.6772 

inches) from the short end of the module can be used for the module to meet 5400 Pa design 

strength. 

 

3.2 Mounting with Clamps 

 

Clips and clamps are not provided by BenQ Solar. 

 

The clamping clips on the side frame must be in parallel – equidistant from the closest 

module frame corner (see Figure 1). 

 

Ensure the clamps are of sufficient design strength to allow for the maximum design 

pressure of the module.   

Summary of Contents for PM060M01

Page 1: ...60 cells with light weight series Mono 60 cells with light weight series Mono 60 cells with light weight series Mono 60 cells with light weight series PM060M0 PM060M0 PM060M0 PM060M0X X X X Poly Poly...

Page 2: ...2 4 PM060M01 Series 7 2 5 PM072PW0 PM072MW0 Series 7 2 6 PM096B00 Series 8 Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines 9 9...

Page 3: ...t warranty details and limitations Product Warranty version is based on warranty note in effect at the time of product manufacturing date Please download and save a copy of the Warranty Note for refer...

Page 4: ...ING LIFTING AND HANDLING LIFTING AND HANDLING LIFTING AND HANDLING Do not lift the module or carry module by junction box or PV cables Do not drill holes in the frame This will void warranty and may a...

Page 5: ...ass C according to IEC 61730 2 2 2 2 standard In case of roof installation the PV module assemble is to be mounted o standard In case of roof installation the PV module assemble is to be mounted o sta...

Page 6: ...ments Take special steps to cover protect the module connectors When storing the modules turn so that the glass is face down Do not allow water or dust to collect inside module this can damage module...

Page 7: ...1 25 when determining component voltage ratings conductor capacities fuse sizes and size of controls connected to PV output An additional 1 25 multiplier may be required by the NEC for sizing fuses a...

Page 8: ...W x H s L x W x H s L x W x H 1639 x 983 x 35 mm 64 52 x 38 7 x 1 38 in Module Weight Module Weight Module Weight Module Weight 10 5 kg 23 3 lbs Power 265W 270W 275W 280W 285W 290W Efficiency 16 4 16...

Page 9: ...59 x 1046 x 46 mm 61 38 x 41 18 x 1 81 in Module Weight Module Weight Module Weight Module Weight 18 6 kg 41 3 lbs Power 315W 320W 325W 327W 330W Efficiency 19 3 19 6 19 9 20 1 20 3 Vmp V 54 7 54 7 54...

Page 10: ...S BELOW COULD AFFECT MAX WIND LOAD AFFECT MAX WIND LOAD AFFECT MAX WIND LOAD AFFECT MAX WIND LOAD AND OR PRODUCT WARR AND OR PRODUCT WARR AND OR PRODUCT WARR AND OR PRODUCT WARRANTY ANTY ANTY ANTY 3...

Page 11: ...s mounting option only the existing mounting holes with the current diameter of 8 8 8 8mm mm mm mm can be used for module to meet 5400Pa design strength under UL 1703 PM PM PM PM072 072 072 072P P P P...

Page 12: ...clip of clamp equal to module frame height d Recommended bolt torque refer to item 3 1 Installation guide a Please check the center of the clamps alignment with mounting points b The ranges of mounti...

Page 13: ...clamping methods available see Clamp Location Details below for specific measurements o Clamp on the long side of the frame see Figure 2 measurements below o Clamp on the short side of the frame see...

Page 14: ...13 Figure Figure Figure Figure 2 2 2 2 Long rail mounting clamp range D1 and D2 Figure Figure Figure Figure 3 3 3 3 Short rail mounting clamp range D3 and D4...

Page 15: ...n PM060MB3 205mm 8 07in 271mm 10 67in 124 mm 4 88 in 198 mm 7 80 in PM060MBR 205mm 8 07in 271mm 10 67in 124 mm 4 88 in 198 mm 7 80 in PM072PW0 130mm 5 11 in 490 mm 19 29 in PM072PWA 130mm 5 11 in 490...

Page 16: ...e PM PM PM PM060 060 060 060M01 Module Clamp Location Details M01 Module Clamp Location Details M01 Module Clamp Location Details M01 Module Clamp Location Details Long rail Long rail Long rail Long r...

Page 17: ...NT Do not bend the cable directly behind the contact point A minimum bending radius of r 4x static steady r 5x dynamic cable diameter must be maintained The cable must be routed in a way that tensile...

Page 18: ...or the best possible performance The module s performance will be enhanced Do not install modules in systemic and ongoing shade this can cause the temperature of exposed cells to rise reducing output...

Page 19: ...d connectors 4 2 Module Grounding BenQ Solar PV modules have a clearly marked grounding hole on each side of the frame for inserting the ground contact The grounding screw and bolt are usually sold se...

Page 20: ...through use of clamps that penetrate the anodization in conjunction with grounding of the mounting system or through direct grounding of the frames by attaching a copper wire to a grounding hole of e...

Page 21: ...rantees their insulation up to a DC voltage of The UL 1703 certificate of these modules guarantees their insulation up to a DC voltage of The UL 1703 certificate of these modules guarantees their insu...

Page 22: ...roppings collecting on the module surface Thin layers of dust normal soiling that reduce the sun s intensity evenly are not dangerous and the power reduction is not as significant as other debris Clea...

Page 23: ...anodic oxide coatings is generally every six months When cleaning be sure not to damage or scratch this coating Dirt on the frame can generally be cleaned off using warm mildly soapy water and a fiber...

Page 24: ...uildings and those intended to be freestanding To satisfy the listing for this product the modules must be mounted with a rack or standoff structure It does not include integration into a building sur...

Page 25: ...new model PM096B01 PM245P03 2 Modify the typo of PM096 clamping area 1 3 2014 06 30 Add new model PM060P00 1 4 2014 07 01 Add new model PM048M00 PM060M01 PM060M02 2 0 2014 12 11 Add new model PM072P00...