background image

                                                     

                               

                                                                       

18

 

 

Do not climb up or walk on the module.   

 

Do not drop the module or throw objects on the module. 

 

Use the module only for the purpose to which it is designed.   

 

Do not dismantle the module or remove any part, label, or piece assembled by the 

manufacturer without the manufacturer’s authorization.   

 

Do not concentrate sunlight or other artificial light sources onto the module. 

 

Use tools duly coated with insulating material while working with the modules. 

 

Always work under dry conditions. 

 

Do  not  install  the  modules  where  there  may  be  flammable  gases  or  vapors,  since 

sparks may be produced. 

 

Take care to avoid electric discharges when installing, wiring, starting up or carrying 

out maintenance work on the modules. 

 

Do not touch the terminals while the module is exposed to light.   

 

Install with suitable protection to redirect a discharge of 30 or more direct current 

volts to if delivered any person on the installation team. 

 

Please prevent adherent of oil such as paraffin liquid, animal oil and vegetable oil form 

molding  parts.  It  may  be  cracked  or  broken  and  loose  the  performance of  Junction 

Box and connectors. 

 

4.2 Module Grounding   

BenQ Solar PV modules have a clearly marked grounding hole on each side of the frame for 
inserting the ground contact. The grounding screw and bolt are usually sold separately from 
the mounting equipment. 
 
Please  make  sure  the  grounding  screw  breaks  the  anodized  surface  of  the  module  frame 
around  the  holes.  Another  option  is  to  scratch  off  the  anodizing  before  the  grounding 
connection is made.    The frame is fully insulated by the anodizaiton process, so this step is 
essential for proper ground contact.. 
 
An anti-oxidation compound should be applied to the bare aluminum surface for protection. 
Use a layer of insulation if the support structure material is different than the frame material 
(aluminum) to prevent galvanic corrosion. 
 
If the support structure is a non conductor, a dedicated ground cable must be connected to 
each  module  frame  by  means  of  a  suitable  fastening  system.  The  fastening  system  must  be 
spliced  with  a  cable  that  has  a  minimum  diameter  of  2.5mm

2

..  Please  make  sure  that  each 

module is grounded properly per local municipal requirements. The recommended assembly 
of grounding screw is shown below in Figure 5. 
 

Note: When using a Tapping Screw for grounding, the cap washer is used for buffer only and can be substituted 

by any M4-M4.5 washer.                                                           

Summary of Contents for PM060M01

Page 1: ...60 cells with light weight series Mono 60 cells with light weight series Mono 60 cells with light weight series Mono 60 cells with light weight series PM060M0 PM060M0 PM060M0 PM060M0X X X X Poly Poly...

Page 2: ...2 4 PM060M01 Series 7 2 5 PM072PW0 PM072MW0 Series 7 2 6 PM096B00 Series 8 Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines 9 9...

Page 3: ...t warranty details and limitations Product Warranty version is based on warranty note in effect at the time of product manufacturing date Please download and save a copy of the Warranty Note for refer...

Page 4: ...ING LIFTING AND HANDLING LIFTING AND HANDLING LIFTING AND HANDLING Do not lift the module or carry module by junction box or PV cables Do not drill holes in the frame This will void warranty and may a...

Page 5: ...ass C according to IEC 61730 2 2 2 2 standard In case of roof installation the PV module assemble is to be mounted o standard In case of roof installation the PV module assemble is to be mounted o sta...

Page 6: ...ments Take special steps to cover protect the module connectors When storing the modules turn so that the glass is face down Do not allow water or dust to collect inside module this can damage module...

Page 7: ...1 25 when determining component voltage ratings conductor capacities fuse sizes and size of controls connected to PV output An additional 1 25 multiplier may be required by the NEC for sizing fuses a...

Page 8: ...W x H s L x W x H s L x W x H 1639 x 983 x 35 mm 64 52 x 38 7 x 1 38 in Module Weight Module Weight Module Weight Module Weight 10 5 kg 23 3 lbs Power 265W 270W 275W 280W 285W 290W Efficiency 16 4 16...

Page 9: ...59 x 1046 x 46 mm 61 38 x 41 18 x 1 81 in Module Weight Module Weight Module Weight Module Weight 18 6 kg 41 3 lbs Power 315W 320W 325W 327W 330W Efficiency 19 3 19 6 19 9 20 1 20 3 Vmp V 54 7 54 7 54...

Page 10: ...S BELOW COULD AFFECT MAX WIND LOAD AFFECT MAX WIND LOAD AFFECT MAX WIND LOAD AFFECT MAX WIND LOAD AND OR PRODUCT WARR AND OR PRODUCT WARR AND OR PRODUCT WARR AND OR PRODUCT WARRANTY ANTY ANTY ANTY 3...

Page 11: ...s mounting option only the existing mounting holes with the current diameter of 8 8 8 8mm mm mm mm can be used for module to meet 5400Pa design strength under UL 1703 PM PM PM PM072 072 072 072P P P P...

Page 12: ...clip of clamp equal to module frame height d Recommended bolt torque refer to item 3 1 Installation guide a Please check the center of the clamps alignment with mounting points b The ranges of mounti...

Page 13: ...clamping methods available see Clamp Location Details below for specific measurements o Clamp on the long side of the frame see Figure 2 measurements below o Clamp on the short side of the frame see...

Page 14: ...13 Figure Figure Figure Figure 2 2 2 2 Long rail mounting clamp range D1 and D2 Figure Figure Figure Figure 3 3 3 3 Short rail mounting clamp range D3 and D4...

Page 15: ...n PM060MB3 205mm 8 07in 271mm 10 67in 124 mm 4 88 in 198 mm 7 80 in PM060MBR 205mm 8 07in 271mm 10 67in 124 mm 4 88 in 198 mm 7 80 in PM072PW0 130mm 5 11 in 490 mm 19 29 in PM072PWA 130mm 5 11 in 490...

Page 16: ...e PM PM PM PM060 060 060 060M01 Module Clamp Location Details M01 Module Clamp Location Details M01 Module Clamp Location Details M01 Module Clamp Location Details Long rail Long rail Long rail Long r...

Page 17: ...NT Do not bend the cable directly behind the contact point A minimum bending radius of r 4x static steady r 5x dynamic cable diameter must be maintained The cable must be routed in a way that tensile...

Page 18: ...or the best possible performance The module s performance will be enhanced Do not install modules in systemic and ongoing shade this can cause the temperature of exposed cells to rise reducing output...

Page 19: ...d connectors 4 2 Module Grounding BenQ Solar PV modules have a clearly marked grounding hole on each side of the frame for inserting the ground contact The grounding screw and bolt are usually sold se...

Page 20: ...through use of clamps that penetrate the anodization in conjunction with grounding of the mounting system or through direct grounding of the frames by attaching a copper wire to a grounding hole of e...

Page 21: ...rantees their insulation up to a DC voltage of The UL 1703 certificate of these modules guarantees their insulation up to a DC voltage of The UL 1703 certificate of these modules guarantees their insu...

Page 22: ...roppings collecting on the module surface Thin layers of dust normal soiling that reduce the sun s intensity evenly are not dangerous and the power reduction is not as significant as other debris Clea...

Page 23: ...anodic oxide coatings is generally every six months When cleaning be sure not to damage or scratch this coating Dirt on the frame can generally be cleaned off using warm mildly soapy water and a fiber...

Page 24: ...uildings and those intended to be freestanding To satisfy the listing for this product the modules must be mounted with a rack or standoff structure It does not include integration into a building sur...

Page 25: ...new model PM096B01 PM245P03 2 Modify the typo of PM096 clamping area 1 3 2014 06 30 Add new model PM060P00 1 4 2014 07 01 Add new model PM048M00 PM060M01 PM060M02 2 0 2014 12 11 Add new model PM072P00...

Reviews: