background image

                                                                                   

2013/7/25

                                                                   

10

 

 

Figure 

Figure 

Figure 

Figure 3

33

3 Short rail mounting clamp range (D3 and D4)

 

    

PM200M00

PM200M00

PM200M00

PM200M00 Module

 Module

 Module

 Module Clamp Location

 Clamp Location

 Clamp Location

 Clamp Location Details

 Details

 Details

 Details    

 

Long rail

Long rail

Long rail

Long rail clamping for 5400 Pa design strength: clamp between 

D1

D1

D1

D1    –

––

–    227

227

227

227    mm

mm

mm

mm    (8

(8

(8

(8.94 in)

.94 in)

.94 in)

.94 in)

 

and 

and 

and 

and D2

D2

D2

D2    –

––

–    296

296

296

296    mm

mm

mm

mm (11.65 in)

 (11.65 in)

 (11.65 in)

 (11.65 in)

 

from the closest short side of the module.   

 

Short rail

Short rail

Short rail

Short rail clamping for 2400 Pa design strength: clamp between 

D3

D3

D3

D3    –

––

–    50

50

50

50    mm

mm

mm

mm (1.97 in) 

 (1.97 in) 

 (1.97 in) 

 (1.97 in) 

and 

and 

and 

and D4

D4

D4

D4    –

––

–    150

150

150

150    mm

mm

mm

mm (5.91 in)

 (5.91 in)

 (5.91 in)

 (5.91 in)

 from the closest long side of the module. 

 

PM245P00 / PM250M01

PM245P00 / PM250M01

PM245P00 / PM250M01

PM245P00 / PM250M01    Module Clamp Location Details

Module Clamp Location Details

Module Clamp Location Details

Module Clamp Location Details    

 

Long rail

Long rail

Long rail

Long rail clamping for 5400 Pa design strength: clamp between 

D1

D1

D1

D1    –

––

–    281

281

281

281    mm

mm

mm

mm (11.06 in) 

 (11.06 in) 

 (11.06 in) 

 (11.06 in) 

and 

and 

and 

and D2

D2

D2

D2    –

––

–    375

375

375

375    mm

mm

mm

mm (14.76 in)

 (14.76 in)

 (14.76 in)

 (14.76 in)

 from the closest short side of the module. 

 

Short rail

Short rail

Short rail

Short rail clamping for 2400 Pa design strength: clamp between 

D3

D3

D3

D3    –

––

–    198

198

198

198    mm

mm

mm

mm (7.8 in) 

 (7.8 in) 

 (7.8 in) 

 (7.8 in) 

and 

and 

and 

and D4

D4

D4

D4    –

––

–    298

298

298

298    mm

mm

mm

mm

 (11.73 in) 

(11.73 in) 

(11.73 in) 

(11.73 in) from the closest long side of the module. 

    

PM

PM

PM

PM3

33

300

00

00

00P

P

P

P00

00

00

00    Module Clamp Location Details

Module Clamp Location Details

Module Clamp Location Details

Module Clamp Location Details    

 

Long rail

Long rail

Long rail

Long rail clamping for 5400 Pa design strength: clamp between 

D1

D1

D1

D1    –

––

–    127

127

127

127    mm

mm

mm

mm (5.0 in) 

 (5.0 in) 

 (5.0 in) 

 (5.0 in) 

and 

and 

and 

and D2

D2

D2

D2    –

––

–    427

427

427

427    mm

mm

mm

mm (16.81 in)

 (16.81 in)

 (16.81 in)

 (16.81 in)

 from the closest short side of the module. 

 

Short rail

Short rail

Short rail

Short rail clamping for 2400 Pa design strength: clamp between 

D3

D3

D3

D3    –

––

–    2

22

221

21

21

21    mm

mm

mm

mm (8.7 in) 

 (8.7 in) 

 (8.7 in) 

 (8.7 in) 

and 

and 

and 

and D4

D4

D4

D4    –

––

–    27

27

27

271

11

1    mm

mm

mm

mm (10.67 in)

 (10.67 in)

 (10.67 in)

 (10.67 in)

 from the closest long side of the module. 

    

PM318B00/PM318B01/PM096B00

PM318B00/PM318B01/PM096B00

PM318B00/PM318B01/PM096B00

PM318B00/PM318B01/PM096B00    Module Clamp Location Details

Module Clamp Location Details

Module Clamp Location Details

Module Clamp Location Details    

 

Long rail

Long rail

Long rail

Long rail clamping for 5400 Pa design strength: clamp between 

D1

D1

D1

D1    –

––

–    2

22

250

50

50

50    mm

mm

mm

mm (9.84 in) 

 (9.84 in) 

 (9.84 in) 

 (9.84 in) 

and 

and 

and 

and D2

D2

D2

D2    –

––

–    400

400

400

400    mm

mm

mm

mm (15

 (15

 (15

 (15.75 in)

.75 in)

.75 in)

.75 in)

 from the closest short side of the module. 

 

Short rail

Short rail

Short rail

Short rail clamping for 2400 Pa design strength: clamp between 

D3

D3

D3

D3    –

––

–    1

11

160

60

60

60    mm

mm

mm

mm (6.3 in) 

 (6.3 in) 

 (6.3 in) 

 (6.3 in) 

and 

and 

and 

and D4

D4

D4

D4    –

––

–    400

400

400

400    mm

mm

mm

mm (15.75 in)

 (15.75 in)

 (15.75 in)

 (15.75 in)

 from the closest long side of the module. 

 

Summary of Contents for PM096B00

Page 1: ...In ns st ta al ll la at ti io on n G Gu ui id de e I IE EC C E ET TL L PM200M00 PM245P00 PM250M01 PM300P00 PM318B00 PM318B01 PM096B00 Version 1 Version 1 Version 1 Version 1 1 1 1 1 Note The content...

Page 2: ...lar Module Specifications 5 2 1 PM200M00 Series 5 2 2 PM245P00 Series 5 2 3 PM250M01 Series 6 2 4 PM300P00 Series 6 2 5 PM318B00 PM318B01 PM096B00 Series 6 2 6 Performance of PV Modules 7 Chapter 3 Mo...

Page 3: ...b AND observe industry b AND observe industry best est est est p p p practices ractices ractices ractices may may may may result in result in result in result in dangerous conditions and could dangero...

Page 4: ...affect module performance Do not stand on drop scratch or allow objects to hit modules especially module glass Do not install or handle the modules when wet or during periods of high wind Do not insta...

Page 5: ...module Do not attempt to change or repair any part of the module Damaged modules broken glass torn back sheet broken j boxes broken connectors etc can present electrical hazards as well as laceration...

Page 6: ...x 38 70 x 1 57 in Module Weight Module Weight Module Weight Module Weight 15 4 kg 33 5 lbs ModuleType Pmax W Voc V Isc A Vmp V Imp A PM200M00_190 190 30 2 8 60 23 6 8 06 PM200M00_195 195 30 3 8 68 23...

Page 7: ...983 x 50 mm 77 01 x 38 70 x 1 96 in Module Weight Module Weight Module Weight Module Weight 28 kg 61 73 lbs ModuleType Pmax W Voc V Isc A Vmp V Imp A PM300P00_290 290 44 9 8 69 35 6 8 15 PM300P00_295...

Page 8: ...determining component voltage ratings conductor capacities fuse sizes and size of controls connected to PV output An additional 1 25 multiplier may be required by the NEC for sizing fuses and conduct...

Page 9: ...x wind load and or product warranty affect max wind load and or product warranty affect max wind load and or product warranty affect max wind load and or product warranty 3 1 Mounting with Screws Secu...

Page 10: ...of the mounting clamp to the edge of the module frame Clips and clamps are not provided by BenQ Solar There are two clamping methods available see below for specific measurements o Clamp on the long s...

Page 11: ...D4 D4 D4 D4 298 298 298 298 mm mm mm mm 11 73 in 11 73 in 11 73 in 11 73 in from the closest long side of the module PM PM PM PM3 3 3 300 00 00 00P P P P00 00 00 00 Module Clamp Location Details Modu...

Page 12: ...ble Pay attention to the following when wiring 1 1 1 1 Correct wiring scheme Correct wiring scheme Correct wiring scheme Correct wiring scheme Check that the wiring is correct before commissioning the...

Page 13: ...to where they are ordered Should they be supplied without cables it is recommended that cables with cross sections between 4 and 10 mm2 be used The cables which allow easy handling while providing hig...

Page 14: ...izing from the surface of the grounding holes or scratch off the anodizing before the grounding connection is made since the frame is fully insulated by anodizing An anti oxidation compound should be...

Page 15: ...lamps that penetrate the anodization in conjunction with grounding of the mounting system or through direct grounding of the frames by attaching a copper wire to a grounding hole of each module bolt s...

Page 16: ...xes can be used to enable greater cable cross section area for long distance transmission The modules are qualified for the application class A Hazardous voltage IEC 61730 higher than 50V EN 61730 hig...

Page 17: ...ppings collecting on the module surface Thin layers of dust normal soiling that reduce the sun s intensity evenly are not dangerous and the power reduction is not as significant as other debris Clean...

Page 18: ...es include an anodic oxide coating to increase produce life The cleaning cycle for regular anodic oxide coatings is generally every six months When cleaning be sure not to damage or scratch this coati...

Page 19: ...f the connection cable junctions Check the junction box sealing Should sealing faults be observed the items which have been affected should be replaced and cleaned Contact BenQ Solar for additional in...

Page 20: ...product meets or exceeds the requirements set forth by UL1703 for PV Modules This UL1703 Standard covers flat plate PV modules intended for installation on buildings and those intended to be freestan...

Reviews: