background image

                                                                                   

2013/7/25

                                                                   

16

 

Chapter 

Chapter 

Chapter 

Chapter 5

55

5    Maintenance

Maintenance

Maintenance

Maintenance    

 

Inspect all modules annually for safe electrical connections, sound mechanical connection, 

and corrosion. 

 

BenQ  Solar  PV  module may  use anti-reflective  coating  (ARC)  glass  to  enhance  power 

output. 

 

Do  not  to  touch  glass  surface  unless  wearing  clean  gloves  in  order  to  prevent 

fingerprints or smudges on the ARC. Fingerprints may be removed with standard glass 

cleaner. 

 

Periodically clean  glass  and  the  module  surface  only  with  a  soft  cloth  or  sponge  using 

mild detergent and water.   

 

Do  not  use  harsh  cleaning  materials  such  as  scouring  powder,  steel  wool,  scrapers, 

blades, or other sharp instruments to clean the glass surface of the module. Use of such 

materials will void the product warranty. 

 

5.1 Module Cleaning Guidelines 

Dirt piled up on the module’s transparent surface reduces its performance and may cause the 

module hot spot effect. This problem may become serious in the case of industrial waste and 

bird droppings collecting on the module surface.   

 

Thin layers of dust (normal soiling) that reduce the sun’s intensity evenly are not dangerous 

and the power reduction is not as significant as other debris.   

 

Clean  the  module  array  regularly  to  address  reduced  production  due  to  soiling.    The 

frequency of cleaning depends on how quickly material accumulates. Mounting the module at 

or above a 15 degree angle will help prevent dust and debris from collecting on the module. 

 

In  many  cases,  rainfall  may  reduce  or remove  the  need  to  clean  the  modules.  It  is  best  to 

clean the module during early morning, late afternoon or cloudy day. Do not clean module 

during  high  temperature,  temperature  lower  than  zero  degrees  Celsius,  or  any  time  when 

there is a large temperature difference between module and cleanser.   

If it is necessary to clean back side of module, do not damage any components. Avoid allowing 

any oily liquids such as paraffin liquid, animal oil, or vegetable oil contacting with junction box, 

cable and connector.    BenQ Solar PV modules can withstand snow pressure of 2400 Pa.(UL 

1703) Please use soft brush lightly removing snow pileup. Do not try to remove frozen snow 

and solid ice on the module (it will eventually melt off). 

 

Summary of Contents for PM096B00

Page 1: ...In ns st ta al ll la at ti io on n G Gu ui id de e I IE EC C E ET TL L PM200M00 PM245P00 PM250M01 PM300P00 PM318B00 PM318B01 PM096B00 Version 1 Version 1 Version 1 Version 1 1 1 1 1 Note The content...

Page 2: ...lar Module Specifications 5 2 1 PM200M00 Series 5 2 2 PM245P00 Series 5 2 3 PM250M01 Series 6 2 4 PM300P00 Series 6 2 5 PM318B00 PM318B01 PM096B00 Series 6 2 6 Performance of PV Modules 7 Chapter 3 Mo...

Page 3: ...b AND observe industry b AND observe industry best est est est p p p practices ractices ractices ractices may may may may result in result in result in result in dangerous conditions and could dangero...

Page 4: ...affect module performance Do not stand on drop scratch or allow objects to hit modules especially module glass Do not install or handle the modules when wet or during periods of high wind Do not insta...

Page 5: ...module Do not attempt to change or repair any part of the module Damaged modules broken glass torn back sheet broken j boxes broken connectors etc can present electrical hazards as well as laceration...

Page 6: ...x 38 70 x 1 57 in Module Weight Module Weight Module Weight Module Weight 15 4 kg 33 5 lbs ModuleType Pmax W Voc V Isc A Vmp V Imp A PM200M00_190 190 30 2 8 60 23 6 8 06 PM200M00_195 195 30 3 8 68 23...

Page 7: ...983 x 50 mm 77 01 x 38 70 x 1 96 in Module Weight Module Weight Module Weight Module Weight 28 kg 61 73 lbs ModuleType Pmax W Voc V Isc A Vmp V Imp A PM300P00_290 290 44 9 8 69 35 6 8 15 PM300P00_295...

Page 8: ...determining component voltage ratings conductor capacities fuse sizes and size of controls connected to PV output An additional 1 25 multiplier may be required by the NEC for sizing fuses and conduct...

Page 9: ...x wind load and or product warranty affect max wind load and or product warranty affect max wind load and or product warranty affect max wind load and or product warranty 3 1 Mounting with Screws Secu...

Page 10: ...of the mounting clamp to the edge of the module frame Clips and clamps are not provided by BenQ Solar There are two clamping methods available see below for specific measurements o Clamp on the long s...

Page 11: ...D4 D4 D4 D4 298 298 298 298 mm mm mm mm 11 73 in 11 73 in 11 73 in 11 73 in from the closest long side of the module PM PM PM PM3 3 3 300 00 00 00P P P P00 00 00 00 Module Clamp Location Details Modu...

Page 12: ...ble Pay attention to the following when wiring 1 1 1 1 Correct wiring scheme Correct wiring scheme Correct wiring scheme Correct wiring scheme Check that the wiring is correct before commissioning the...

Page 13: ...to where they are ordered Should they be supplied without cables it is recommended that cables with cross sections between 4 and 10 mm2 be used The cables which allow easy handling while providing hig...

Page 14: ...izing from the surface of the grounding holes or scratch off the anodizing before the grounding connection is made since the frame is fully insulated by anodizing An anti oxidation compound should be...

Page 15: ...lamps that penetrate the anodization in conjunction with grounding of the mounting system or through direct grounding of the frames by attaching a copper wire to a grounding hole of each module bolt s...

Page 16: ...xes can be used to enable greater cable cross section area for long distance transmission The modules are qualified for the application class A Hazardous voltage IEC 61730 higher than 50V EN 61730 hig...

Page 17: ...ppings collecting on the module surface Thin layers of dust normal soiling that reduce the sun s intensity evenly are not dangerous and the power reduction is not as significant as other debris Clean...

Page 18: ...es include an anodic oxide coating to increase produce life The cleaning cycle for regular anodic oxide coatings is generally every six months When cleaning be sure not to damage or scratch this coati...

Page 19: ...f the connection cable junctions Check the junction box sealing Should sealing faults be observed the items which have been affected should be replaced and cleaned Contact BenQ Solar for additional in...

Page 20: ...product meets or exceeds the requirements set forth by UL1703 for PV Modules This UL1703 Standard covers flat plate PV modules intended for installation on buildings and those intended to be freestan...