background image

4

 

Special Opera ons of the AC Hot Water 

 

Dry Mode  

Removes moisture from the air in high humidity by cycling the indoor 
fan o

 or to very low speed. 

Cooling Only  

Use the system the same as you would use any air condi oning system, 
set you air movement 

flaps

 to suit the room. Recommended 

temperature to be set to is 24`C, however every 1`C increase may save 
as much as 10% on your running costs. 

ng only 

Use the system the same as you would use any air condi oning system, 
set you air movement 

flaps

 to suit the room. Recommended 

temperature to be set to is 22`C, however every 1`C decrease may save 
as much as 10% on your running costs. 

Auto  

This will select a temperature displayed on the screen in the centre of 
the unit and maintain it in h

ng or cooling. (not a recommended 

ng) 

Hot Water Only 

The system can be manually switched on now, Via a wall switch or a 

 clock and smart systems to gain advantage of 

off

 peak power. The 

infra red controller can also switch the system on. The water is 
automa cally controlled to a set temperature of 60`C.  

Cooling and Hot Water 

You operate your system as a normal air condi oner and while you are 
doing so it he ng your hot water for Free. 

ng and Hot Water 

Because of the unique design of the system, the indoor unit will only 
start to func on when the tank temperature is above 32`C. If hea ng is 
required straight away then turn o

 your hot water(remember to turn 

back on later, or switch the system to hot water only 

l it reaches 

32`C and then turn the he

g on as well. 

Auto and Hot Water 

Same as Cooling and 

ng modes 

Dry and Hot Water  

Func on not available. Hot Water is not produced in the func on as the 
op

on of the system is not conducive to produce hot water. 

 

 

 

Smart System 

The Hot Water Smart System will monitor if the compressors opera on 
in Auto, Cooling and Hea ng, if the compressor does not operate for 
One hour, the system will switch to Heat Pump hot water mode. The 
Smart System was designed if you accidentally forget to turn o

 your 

aircondi oner and the house/room has cooled down over night and you 
or your family shower in the morning, the hot water system would have 
started to heat the water because of the Smart System. 

 

The compressor needs to run to generates all the heat that heats your 
families water. 

 

Summary of Contents for BENDX ACHW 34

Page 1: ...AIR CONDITIONER WATER HEATER OPERATION MANUAL...

Page 2: ...ury or death Disconnect and lock off power before servicing equipment SPECIAL FEATURES OUTLINES AND DIMENSIONS WIRING DIAGRAMS SAFETY PRECAUTIONS BEFORE INSTALLATION INSTALLATION REMOTE CONTROLOPERATI...

Page 3: ...with refrigerant pipe submerge into water tank ACHW incorporate high efficiency Twin copper tube heat exchanger that circulates the the water in and out of the tank This unique safety feature renders...

Page 4: ...gn filter is slide out type which can be easily removed at the air inlet grille for cleaning WIRELESS REMOTE CONTROL The compact LCD transmitter is able to operate the air conditioner unit within the...

Page 5: ...emperature setting Operation display To set the desined room temperature press the button to increase or decrease the set temperature The temperature setting range is 16 31 C Summer and winter 24 C C...

Page 6: ...60 C Cooling and Hot Water You operate your system as a normal air condi oner and while you are doing so it he ng your hot water for Free ng and Hot Water Because of the unique design of the system th...

Page 7: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 34 BENDX ACHW 34 5...

Page 8: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 41 BENDX ACHW 51 BENDX ACHW 41 BENDX ACHW 51 6...

Page 9: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 65 BENDX ACHW 65 7...

Page 10: ...NK 8 This tank is a guide only for connection installation may vary with tanks supplied Specifications subject to change for product improvements 650kPa P and T Valve Be fitted Recommended filter or s...

Page 11: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 34 41 and 51 Model 34 41 and 51 9...

Page 12: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 65 Model 65 10...

Page 13: ...code Green and yellow Earth Blue Brown Live Neutral As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plu...

Page 14: ...fire ignition Confirm drainage piping is connected properly If it is not connected perfectly it may cause water leakag this is the installers Liability and should be checked at commisioning Confirm th...

Page 15: ...6 INSTALATION 13 Cycle Water Inlet Cold Water Inlet Cycle Water Outlet Pressure Regulator Valve is required 500kPa Mixing Valve V 50 C...

Page 16: ...cooler air can be evenly distributed See fig 1 Ensure that air discharge is not short circuited with air intake Ensure that wall is sufficiently strong rigid flat perpendicular and vibration free Wher...

Page 17: ...in and distribute plenty of air thus lowering the condensing temperature A place capable of bearing the weight of the outdoor unit and isolating noise and vibration A place protected from direct sunl...

Page 18: ...he desired location on the wall and mark the holes location accordingly Ensure that the minimum maintenance and servicing space at the top left and right side of the units is reserved Ensure also the...

Page 19: ...ressor or any moving parts of fan motors The field wires from the indoor unit must be clamped on the wire clamp 4 REFRIGETANT PIPING MODEL PIPE D mm IMPERIAL DLE RIGED DIE A mm 6 35 1 4 1 3 9 52 3 8 1...

Page 20: ...500 microns note R290 connected to Hhandle evacuate to bottle tap Refer to figure at right to connect stop valve gas charging hose mixing valve and vacuum pump Use vacuum pump 76cmHg stop valve liquid...

Page 21: ...ons foreign matters etc Every 12 months Every 12 months Compressor 1 No maintenance needed if refrigerant circuit remains sealed However check for refrigerant leak at joints and fittings Every 12 mont...

Page 22: ...se of Loose connections Indoor temperature sensor failure E1 Check if sensor is short circuit Indoor pipe temperature sensor failure E2 Check if sensor is short circuit Outdoor system failure E4 Outdo...

Page 23: ...tive 2 Non condensable gases in refrigerant circult e g oil 3 Obstructed air intake discharge 4 Short circuiting of hot air at condensing unit Too low Too high Normal A little Low A little High Data P...

Page 24: ...itioner is disconnected from main power source e Fuse blown or circuit brealer off ii Diagnosis of Refrlgerant Circuit Application There might be some cases where the unit starts running but does not...

Page 25: ...on the flare surface however be very careful not to get any in the inside of the pipe can cause blockages minimal can be used on the thread torque settings still apply The torque Settings liquid 37 N...

Page 26: ...w these may need to be bridge for charging Start the system and continue charging very slowly as the gas maybe sucked in very quickly avoid Liquid refrigerant going directly into the compressor Check...

Page 27: ...line lter supplied warranty void if not Cold water in Water is taken from a ng approximately 300mm above the om of the tank and is heated and returned into a ng 100mm lower Air Purging Leave the retur...

Page 28: ...performance will be reduced the system uses the outdoor unit to absorb heat from the atmosphere if the temperature is low the heat absorp on will be less and the hot it is the more heat is absorbed an...

Page 29: ...and all relevant state and territory regulations 10 Defrost deice occurs as the heat pump is absorbing heat from the atmosphere and at low ambient condi ons frost or ice may form The system will autom...

Page 30: ...operated and maintained as per the instruc s supplied 3 The warranty covers the Benson Global system only and not any addi onal parts supplied during the installa on including the tank 4 Warranty is...

Page 31: ...essed in the Warranty Terms and con ons 4 Claims for damages caused directly or indirectly by leakage from the system 5 All damages or breakages is not covered by this warranty and should be added to...

Page 32: ...elow In the event the system has water leaking from the top sec on of the unit a Benson Global authorized agent should be called to check the system Do not a mpt to repair the system yourself this can...

Page 33: ...s that A3 refrigerants R290 shall be permitted only is systems with a refrigerant change of up to 1 5kg for each individual system provided sudden loss of refrigerant could not raise the concentration...

Reviews: