P
ag
e
77
Overhung Balance Flowchart:
Overhung Balancing
.
Similar to Dual plane, as you balance 2
planes.
SETUP:
Enter Setup information
Enter Tolerance information.
Attach tachometer to the Aux. channel,
accelerometers to Channel 1 and Channel
2 on the Impaq. Mount the tach and
accelerometers to your rotor as shown in
the diagram to the left. Be sure to mount
CH1 accelerometer to the closest bearing
of Plane 1 and CH 2 accelerometer
according to the diagram at left.
Incorrect positioning will cause difficulty
with your balance job.
INITIAL RUN:
Start Rotor.
Press [Start] on the impaq.
Press [Start] on the impaq again.
Press [OK] on the navigation keypad.
Stop Rotor.
TRIAL WEIGHT RUN 1:
Enter information on the trial weight on
plane 1 display. Place weight on the
rotor.
Start Rotor.
Press [Start] on the impaq.
Press [Start] on the impaq.
Press [OK] on the navigation keypad.
Stop Rotor.
Remove the Trial weight (or remain)
from the rotor, depending on your initial
setup.