BGSM-100/120
43
G
G
G
G
G
LE failure timeout:
The
time
in seconds (between 10 and 3600 seconds) may be entered in this box; once this time
has elapsed the device will indicate a
Breakdown
on the
LE
terminals.
,
,
,
,
,
The time may increase up to 60 seconds if some telephone devices are connected to the terminals LI.
LE restore timeout
: The
time
in seconds (between 30 and 3600 seconds) may be entered in this box; in this period the
connection of the
LE
terminals must be restored, otherwise the device will indicate a
Breakdown
on the
LE
terminals.
System (BGSM-120 series only)
This section refers to the System.
SIM Phone Number
: Enter the telephone number corresponding to the SIM CARD in this box (maximum 16 digits).
Auto Clock Adjusting
: Checking this option the device will update the system date and time by sending an SMS itself.
SMS Service Center Address
: enter the number of the SMS services centre. It is recommended that you load the option
first, when the Communicator has initialised, to check whether the SIM CARD has this information.
Pay As You Go (BGSM-120 series only)
,
,
,
,
,
The pre-paid SIM CARD credit management service may be suspended at any time, at the discretion of each
individual GSM network operator.
This section can be used to send an SMS providing credit balance information (supplied by the operator) to the first number
in the phonebook at regular intervals. Program the following options for a correct credit balance check request, in accordance
with the type of operator used:
Enquiry Type
: selection of enquiry type (SMS, Call, Service Command).
Enquiry Number
: telephone number to call or to which an SMS message should be sent in order to request credit balance information.
Balance Message
: string used to send SMS messages and to make requests via service commands.
Interval
: Enter the interval (HH-DD) at which you wish to send a perodic SMS containing credit balance information (if
supported by your telephone operator). The interval consists of the following values:
— (HH) next message time - Select the time at which you wish to send the next periodic SMS. The interval for these
values may be set between 0 and 23.
—- (DD) next message day - Select the day on which you wish to send the next periodic SMS. The interval for these
values may be set between 0 and 365.
Outputs(BGSM-100 series only)
This section may be used to set the operating modes of the outputs.
Output 1
,
Output 2
,
Output 3
: Check the box for output operation normally closed or normally open.
Output 3 ON Time:
The
ON time
in seconds may be entered in this field (between 0 and 86400 seconds).
Primary Path
The user can program the primary communication line.
Primary Path:
Select the primary GSM or PSTN line using this field.
GPRS
This page outlines the GPRS configuration options.
,
,
,
,
,
Bearing in mind the delays which may occur in transmission via GPRS, which are caused by the activities of the
network manager, we recommend you program as many call attempts to the burglar alarm control panel as
possible, and that you also provide a backup telephone number which transmits alarms via GSM as well as via GPRS.
Access Point Name 1 and Access Point Name 2
Enter the
Access Point Name
of the GPRS service provider being used. Enter the name of the IP address service provider
in this box.
Access Point Name 2
is considered a backup parameter.
Example for Italian operators
Options
Vodafone
Wind
TIM
Enquiry Type
Call
Service Command
SMS
Enquiry Number
404
40916
Balance Message
*123#
PRE CRE SIN