21
Section 2 - Installation
2.
Connect the Keypad to the Control panel BPI BUS (ter, C, R, -).
3.
Remove the jumper [
54
]:
after several seconds the keypad will emit a beep, and the 4 LEDs on the left
(“
A
” in Figure 2.1) will turn ON;
the four pairs (up/down) of LEDs (“
B
” in Figure 2.1) will simulate 4 DIP
microswitches;
one of the first pair of LEDs will blink to indicate access to the Addressing phase.
4
. Assign an Address to the Keypad (“
B
” in Figure 2.1 shows Address 4).
Use
A
or
B
to select the LED/DIP switch position.
Use
C
or
D
respectively, to turn the LED ON or OFF, in accordance
with the following logic:
Upper RED LED ON
= DIP switch
ON
Lower RED LED ON
= DIP switch
OFF
If you wish to delete the setting and restart, press
e
.
5.
Press
E
to confirm the selected Address:
after several seconds the Keypad will emit an audible signal, and the 4 LEDs on
the right (see “
C
” in Figure 2.1) will turn ON to indicate access to the
Proximity
Reader
Addressing phase (see “
D
” in Fig. 2.1 for the respective LEDs).
If you DO NOT wish to use the
Proximity Reader
, press
o
. The
ALISON/32L will step back to the
Keypad
Addressing phase, at which
point go to step
8.
in this section.
If you wish to use the
Proximity Reader
, go to step
6.
6.
Following the instructions in step
4.
, assign an Address to the
Reader
.
If you wish to delete the setting and restart, press
e
.
NOTE:
After deleting the setting, the ALISON/32L will step back to the
Keypad
Addressing phase
.
7.
Once you have assigned the
Keypad
and
Reader
Addresses, press
E
to
confirm. The Keypad will emit an audible signal and will go back to step
4.
,
this will not affect the setting, but is simply due to the circular organization
of the programming process.
8.
Re-insert the Jumper
[54]
, in accordance with the selected BPI Level (refer to
“Setting up the BPI Level”), then replace the frontplate.
ALISON/S and ALISON/DVP Keypads
1.
Generate Tamper status by removing the case.
2.
Connect the Keypad to the Control panel BPI BUS.
3.
Remove the Jumper
54
— after several seconds the Keypad will emit an
audible signal (long beep) to indicate access to the programming phase.
4
. Alison/S
- Go to step 5
Alison/DVP
- Using keys
AAAAA
or
BBBBB
, select
“
ALISON/DVP
ALISON/DVP
ALISON/DVP
ALISON/DVP
ALISON/DVP
”, then press
E
to confirm.
Summary of Contents for KYO 32 M
Page 1: ...0 1 7 167 7 21 0 18 ...
Page 10: ...10 Multifunction Control Panel The NC2 TAST LED Keypad Figure 1 3 The NC2 TAST LED Keypad D D ...
Page 71: ...71 Section 3 Programming from PC 5 11 6 0 1 2 3 1 4 3 3 5 2 3 0 1 2 3 ...
Page 88: ...ISTISBLEUNKYO 2 6 160108 P70 17 6 85 7 6 U O 01 02 5HF FOLQ LQ RU WLRQ ...