65
Section 3 - Programming from PC
(the ‘Callback’ option must be enabled). If several Teleservice numbers have been
listed in the ‘Telephone’ page, you can select the required number from the drop-
down list (click the down arrow to open the drop-down list).
Test Event
The Test event will be generated at regular intervals, as per programming. This
event will activate the Digital, Voice and Teleservice calls, in accordance with
the ‘Test Event’ settings in the ‘Events’ page.
z
Teleservice Test call
- This option will allow the Control panel to send the ‘Test’
call (Teleservice) automatically at regular intervals (as per programming) to the
‘Installer Telephone Number’. If you DO NOT want to Enable the Test call, enter
‘
00
’ for
Event Code
in the
‘445-Test Event’
field (
330
for Kyo16D and
265
for Kyo4/8, refer to the
Events page
).
z
Send Test programming
- This field is for the Date and Time of the ‘Test’
event.
To view the Date and Time of the successive ‘Test’ event — click the
Download button.
To send a New Date and Time to the Control panel — click the ‘Send Test
programming’ check box then click the Upload button.
z
Time/Interval
- This field is for the interval (in hours) between ‘Test’
events. To Disable the ‘Test’ event, enter ‘
0
’.
z
Date/Hour
- This field will allow you to View and Set the Date and Hour
of the ‘Test’ event.
Figure 3.11 - Teleservice Page