Section 3 - Programming from PC
zone number will be specified in the Event Buffer).
If this option is enabled, Zone 32 cannot be programmed as “Wireless”.
z
Special button on Wireless Key (5)
- If this option is enabled, the
‘B
Mode’
button on the Wireless key (
G
) will not Arm the system, but will
perform the function of SuperKey 2.
z
Future Use (6)
- Reserved.
DO NOT SELECT!
z
Teleservice Test call (7)
- Refer to the ‘Teleservice’ page.
z
Future Use (8)
- Reserved for Future use (Inactive).
z
Reset alarm memory denied to installer code (9)
- If this option is
enabled —
only
the Main User and User Codes will be able to delete the
Alarm memories.
z
Reset tamper memory denied to user code (10)
- If this option is enabled
—
only
the Installer Code will be able to delete the Tamper memories.
z
Bypass tamper on zone (11)
- If this option is enabled, the Control panel
will inhibit ‘Tamper on zone’ when the zone is bypassed.
A
The IMQ-SECURITY SYSTEM approval applies only when the
“
By-
pass tamper on zone
” option is disabled.
z
Real time zone restore (12)
- If this option is enabled, the Control panel
will signal ‘Reset Zone’ as soon as the zone is restored, regardless of the
status of the Alarm cycle.
z
Arming/disarming signalling changeover (13)
- For CESA and CON-
TACT-ID reporting protocols: if this option is enabled, it will be possible
to invert the significance of the digits used to transmit Activation/Restore
messages to the Central station (for Arming/Disarming operations only).
z
2 way audio alert (14)
- If this option is enabled, the Control panel will
open a ‘Talk’ channel for 15 seconds before starting the Listen-in session.
z
Call all telemonitoring numbers (15)
- If this option is enabled, the
Control panel will call all the programmed Telemonitoring numbers for each
event. If this option is disabled, the Control panel will stop the call cycle as
soon as it recognizes a
Successful Call
.
z
(Kyo 4-8-32 Series)
Call all voice numbers (16)
- If this option is enabled,
the Control panel will call all the programmed Voice numbers for each single
event. If this option is disabled, the Control panel will stop the call cycle as
soon as it recognizes a
Successful Call
.
z
(Kyo16D) Programmable Output Relais (16)
-
If this option is enabled
,
the Output terminals of Alarm Relais will work as a ’Programmable Output’
instead that as ‘Alarm Output’. This function applies on the Output n. 1.
A
The IMQ-SECURITY SYSTEM approval applies only when the "Relay
Output Programmable" is disabled.
z
Instant mains trouble signalling (17)
- If this option is enabled, the
Control panel will signal ‘Mains Failure’ immediately. Normally ‘Mains
Failure’ is signalled 15 minutes after black-out.