26
Bentone
165 105 14
7. Instructions Pump
7.1 SUNTEC AT2 45C, AT2 55C
Technical data
One or two-pipe system.
Viscosity range::
2-12 mm
2
/s
Pressure range::
8-25 bar
Rated voltage of coil:
220/240V
50/60 Hz
Oil temperature::
max 60°C
Components
1. Suction line G 1/4”
2. Return plug
3. Nozzle outlet G 1/8” Stage 2 and
stage 1
4. Pressure gauge port G 1/8”
5. Vacuum gauge port G 1/8”
6. Pressure adjustment Stage 1
7. Pressure adjustment Stage 2
8. Pressure adjustment
9. Solenoid valve 1
10. Solenoid valve 2
Summary of Contents for B 30 2A
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone com ...