Summary of Contents for B30A RME

Page 1: ...Providing sustainable energy solutions worldwide 178 080 51 2015 03 11 Installation and maintenance instruction B30A RME B40A RME...

Page 2: ......

Page 3: ...3 GENERAL INSTRUCTIONS___________________________________ 7 4 MAINTENANCE OF OIL BURNER B30______________ 10 5 MAINTENANCE OF OIL BURNER B40______________ 11 6 OIL CIRCUIT DIAGRAM_____________________...

Page 4: ...5 Ignition cable 6 Ignition transformer 7 Photo cell 8 Control box 9 Reset button 10 Cover inspection glass 11 Fan wheel 12 Motor 13 Nozzle assembly adjustment 14 Blast tube 15 Air adjustment 16 Air d...

Page 5: ...er tube B30 Length of burner tube Measure B L 150 115 L Standard 222 187 L 350 315 Burner tube B40 N Standard 202 172 N 302 272 2 2 Dimensions B40A 175 382 B 372 108 108 220 281 303 195 400 126 114 B...

Page 6: ...e net calorific value of 11 86 kWh kg for light oil has been used 7 0 9 0 2 5 3 5 1 0 2 0 TECHNICAL DATA 2 3 Output range and nozzles recommended B30 B40 2 4 Recommended nozzle Because of different bo...

Page 7: ...E RME are and must be equipped with parts designed for this fuel This applies in particular to oil related parts such as the pump solenoid valve oil filter and hoses It is very important when carrying...

Page 8: ...il quantity Raise the flue gas temperature by removing turbulators if any in the boiler Pump adjustment See separate description Maintenance The boiler burner should be examined regularly for any sign...

Page 9: ...n the locking screw B and adjust the nozzle assembly to the desired position Lock the screw B again Air adjustment 0 10 Loosen the stop screw B and turn the knob along the scale to the desired positio...

Page 10: ...doing any service switch off power at the main switch and cut off the oil supply A Service of burner head Open the cover plate and remove the connection hose by undoing screw A 1 Loosen or swing out t...

Page 11: ...doing any service switch off power at the main switch and cut off the oil supply 1 Loosen or swing out the burner from the boiler 2 Loosen 2 fixing screws and withdraw the blast tube Service of burner...

Page 12: ...12 Bentone B30A RME B40A RME 6 OIL CIRCUIT DIAGRAM 1 2 3 1 Nozzle 2 Safety valve 3 Oil pump...

Page 13: ...ansformer Y1 Solenoid valve X1 Plug in contact burner X2 Plug in contact boiler Mains connection and fuses in accordance with local regulations 7 ELECTRIC EQUIPMENT 7 1 OIL BURNER CONTROL LOA21 LOA24...

Page 14: ...attempt to re start 3 4 Operating position If the burner operation is interrupted by means of the main switch or the thermostat a new start takes place when the conditions in accordance with point 1 a...

Page 15: ...09 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14 89 176 152 15 62 185 159 4 50 14 97 177...

Page 16: ...3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 97 201 173 17 62 209 180 18 23 216 186 4 50 18 35 217 18...

Page 17: ...efective oil burner control or flame monitor No oil supply Too great a pressure drop at brake plate Too strong draught prevents flame forming No spark Check and replace fuse as necessary Investigate c...

Page 18: ...x normes et aux documents normatifs suivants et satisfont aux crit res applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivantes 2004 108 EC...

Page 19: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...