9
Bentone
2.4 Setting of brake plate and air flow
a
b
c
ST 146
7,5-9,5
2,0-3,0
3,0-4,0
2.5 Working field ST 146B30A, ST 146B30AV
ST 146B30A
5,0-11,5 kg/h
60-157 kW
ST 146B30AV
5,0-11,5 kg/h
60-136 kW
Type
Motor
Complete
burner
Sound
ST 146 B30A
125W 0,95A 230V
50/60Hz 4µF
230V 0,95A
50Hz
79
dBA ± 0,5
dBA
ST 146 B30AV
125W 0,95A 230V
50/60Hz 4µF
230V 1,15A
50Hz
79
dBA ± 0,5
dBA
2.5.1 Electric Specification
Burner correspond to IP 20
a
b
c
!
*NB It is important that
the spark does not strike
against the brake plate or
nozzle
-0,5
0,0
0,5
1,0
1,5
2,0
2,5
3,0
50
60
70
80
90 100 110 120 130 140 150 160 170
mbar
kW
ST 146B30A
ST 146B30A
V
Summary of Contents for BENTOFLEX ST 146 B30A
Page 32: ...171 905 28...