29
Bentone BFG1
!
When servicing/replacing components which affect the combustion, gas side
leakage analysis and check should be performed on the system.
5.1.6.2 Single electrical package component replacement
1.
Switch off the main current, disconnect the Eurostecker from the
burner and turn off the gas.
2.
Loosen the screw assembling the front piece of the burner and the fan
housing, but not more than that the fan housing can be removed from
the front piece. Disconnect the cables to the multiblock.
3.
Remove the fan housing from the front piece and pull it backwards
until the cables to the ignition electrode and ionisation electrode can be
loosened.
4.
Remove the gas burner control.
5.
Remove the cable of components to be replaced. Disconnect the
cable in the terminal board.
6.
Insert the new cable.
7.
Check that all wires enter the terminal board and that they are securely
fastened.
8.
Switch on the gas burner control.
9.
Assemble the fan housing and front piece.
10. Install the Eurostecker; switch on the main current and open the gas
flow.
11. Start the burner and check the combustion.
When the ignigtion transformer, air switch, gas switch and gas burner control
contained in the electrical package are being replaced, no work needs to be
done in the socket.
Summary of Contents for BFG 1 H1
Page 13: ...13 Bentone BFG1 4 3 5 1 6 2 10 16 9 15 14 13 7 8 22 11 12 2 7 Description ...
Page 47: ...47 Bentone BFG1 Alt 1 Acc to DIN 4791 Alt 2 Alt 3 8 2 Wiring diagram ...
Page 54: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com ...