Par
.
no.
Par
ameter
Number of
elements
T
ype
Edit
V
alue r
ange
Min Max
Reso-
lution
Default
setting
Passwor
d le
vel
161
Number of faults
1
Std_u16
read only
0
65535
1
0
Info / Service
162
Oper
ating hours r
esettable
1
Std_s32
reset
0 h
9999999 h
1 h
0 h
Info / Service
163
Oper
ating hours when unit is live
1
Std_s32
read only
0 h
9999999 h
1 h
0 h
Info / Service
164
Number of startups r
esettable
1
Std_s32
reset
0
9999999
1
0
Info / Service
166
Total number of startups
1
Std_s32
read only
0
9999999
1
0
Info / Service
167
Fuel volume r
esettable [m³, l, ft³, gal]
1
Std_s32
reset
0
99999999
1
0
Info / Service
176
Switching back to pilot
switching cycles
1
Std_s32
read only
0
9999999
1
0
Info / Service
190
Postpur
ging in lockout position
0 = deactivate (no-load position)
1 = active (postpur
ge position)
When active, the
Alarm in the e
vent of start pr
e
vention
function is only possible to a limited e
xtent!
1
Selection
edit
0
1
1
0
SO
191
Function
Switching back to pilot
0 = deactivate
1 = active (lo
w active)
2 = active (high active)
Load contr
oller contacts X5-03 ar
e deactivated when
function is active!
1
Std_u8
edit
0
2
1
0
SO
192
Switching back to pilot
minimum time
1
Time
edit
5 s
120 s
0,2 s
30 s
SO
193
Switching back to pilot
maximum time
1
Time
edit
30 s
108 min.
0,2 s
60 min.
SO
195
Repetition limit heavy oil dir
ect start
1 = no r
epetition
2...15 = 1...14 number of r
epetitions
16 = constant r
epetition
1
Std_u8
edit
1
16
1
3
SO
Summary of Contents for STG 146i/2