07
When
POWER OFF, press the M key and the key for 5 seconds to enter the
advanced setting.
Press the M key to enter the next option, then press the up and down key to adjust,
press the key to exit the advanced option setting mode.
01
02
03
04
05
06
07
08
09
10
Temperature
compensation
The default value of the calibration room temperature is -2
℃
. Press
the up or down key to adjust the range from 9.9
℃
to -9.9
℃
.
Sensor selection
Limit temperature
value modification
The temperature sensor selection defaults to IN. Press the up key or the down key
to adjust it respectively as IN internal sensor selection. ALL means all internal
sensors are selected; OUT means external sensors are set.
The limit temperature value is 35
℃
by default. Press the up or down key to adjust
the range from 5
℃
to 60
℃
.
The default setting temperature difference start is 1
℃
; press the up or down key to
adjust the range from 1
℃
to 10
℃
.
Temperature difference
setting
Advanced Option Setting
Antifreeze function
Set the antifreeze function as OFF by default; press the up key to turn on the
antifreeze function.
Rest day selection
The default setting of rest days is double rest; press the up or down to adjust.
Main and auxili reverse
selection (optional)
Set the main and auxiliary reverse to 0 by default. Press the up or down key to
adjust 0 to turn off the main and additional reverse function, and 02 to indicate the
auxiliary reverse.
Passive linkage output
delay time (optional)
Set the passive linkage delay time as 0 by default. Press the up or down key to
adjust the range of 0-5 minutes.
Set temperature
upper limit
Set the upper limit of the temperature to 60
℃
; press the up or down key to adjust
the range from 35
℃
to 95
℃
.
Reset
Set to restore factory settings. The default display is "-," press the up key to
display "---" and then press the enter key to restore the factory settings.
Operation Guide
1. Power on/off: press the key to turn on/off the thermostat.
2. Press the M key to switch between manual and automatic modes.
3. In the automatic mode, press the key or key to adjust the temperature, and it
will enter the automatic mode, which only runs for a while.
4. Press the key to enter the clock setting, press the mode key M to switch the
setting options, and press the up and down keys to adjust each parameter value.
Note: The time of the WIFI model will automatically obtain the Internet time.
5. Simultaneously press and hold the up and down keys for 5 seconds to add or
cancel the childlock.
6. WIFI link: When the thermostat is turned on, press and hold the up button for five
to eight seconds, the WIFI icon flashes on the thermostat display, and the thermostat
enters the code matching state.
Time programming instructions
Long press the M key to enter the programming setting, short press the M key to
switch options, press the up or down key to adjust the parameters of each option,
and press the 6 key to exit and save mode.