87
Maintenance
EN
6002782_b – 14.09.2016
6.2.2
Changing the lamps
The device is fitted with maintenance-free LED lighting.
In the event of a fault:
☞
Please consult your dealer or customer services.
6.2.3
Replacing the filter filling (only for BUF-BDL
recirculated air filter)
Odours are trapped in the filter filling in the recirculated air
filter. The odour-free, cleaned room air is fed back into the
room.
Recirculated air filters are maintenance-free for up to two
years. Then filter filling must be replaced at regular intervals.
Maintenance intervals
y
Daily use: With odours in the exhaust air or after
12 months at the latest.
y
Occasional use: With odours in the exhaust air or after
24 months at the latest.
D
WARNING
Risk of death due to electric shock.
Touching live parts can cause an
electric shock, burns or death.
The information “Attention Voltage” in the device indicates an
area with live parts.
☞
Never permit any reaching into the area labelled
“Attention Voltage”.
☞
Only remove the cover in order to change the filter filling.
D
ATTENTION!
Danger of property damage through falling parts.
When working on the device, parts of the device or tools
could fall and damage the kitchen equipment.
☞
Protect the cooled hob and other surfaces in the cooking
area (e.g. with thick cardboard).
The device must be in the lower end position.
☞
Disconnect the device from the power supply.
☞
Use an SW 2.5 Allen key to unscrew the screws on the
cover.
☞
Remove the cover upwards. Pay attention to the support
cable and the mains cable.
☞
Take hold of the filter at the handles.
☞
Lift the filter at least 30 cm.
☞
Remove the filter to the front.
☞
Place the filter in a bucket or a similar container.
Summary of Contents for BDL 115 SK
Page 92: ...6002782_b 14 09 2016 ...