23
Operation
6005142_0 – 24.02.2020
EN
4.2.1
Normal operation
D
WARNING
Fire hazard due to grease residue!
In operation grease residue, which is highly inflammable,
collects in and on the device.
☞
Clean the device properly.
D
To achieve optimal efficiency in removing cooking fumes:
☞
Turn the device on 1-2 minutes before you start cooking.
This allows the flow of air to build up, and the fumes are
removed at an early stage.
☞
During the cooking process, switch to a power level that
is appropriate for the intensity of the cooking vapours:
y
Power level 1 - lowest fan power
y
Power level 2 - medium fan power
y
Power level 3 - high fan power
☞
If the intensity of the cooking fumes does not subside,
switch to a higher power level.
☞
Switch to the Power setting when searing. After 6 minutes,
the device automatically switches back to power level 3.
To activate the Power setting permanently,
the corresponding button must be pushed again.
Then the device doesn’t switch back.
☞
Check the fresh air supply at regular intervals.
☞
Use the device also to reduce other unpleasant smells.
Such as from:
y
Onions and garlic
y
Oven, microwave and steamer
y
Fondue and raclette
☞
Turn on the run-on function when you have finished
cooking.
☞
After use, turn the device off. If the automatic run-on
function is activated, the run-on time (10 minutes) starts
in power level 1.
With use of the BackFlow technology, if a power level is
active then a gentle air flow is routed from the air channel
on the underside of the device to the front air inlet. This air
circulation is necessary. The air channel on the underside of
the device must never be closed off.
After 12 hours without operation, the device (including
lighting), the device automatically shuts off.
4.2.2
Extraction mode / recirculated air mode
changeover
If the device is configured for hybrid mode, it is possible to
switch between extraction mode and recirculated air mode
at any time after activating the changeover function.
The changeover function is activated in configuration mode.
D
“4.3 Configuring the device” (page 25).
Button
Function
If the changeover function is activated:
☞
Touch the button one time.
Button glows dimly:
y
The device operates in extraction mode.
y
The wall box is opened.
y
The cleaned air is discharged outdoors.
Button glows brightly:
y
The device is operating in recirculated air
mode.
y
The wall box is closed.
y
The cleaned air is discharged into the
room.
4.2.3
Filter filling indicator
The device has a control indicator to remind the operator
to change the filter filling. If no air circulation filter is used,
the control indicator has no meaning.
The function is set so that the button flashes every 1,000 fan
operating hours (flash duration 120 seconds) as soon as
the device is turned off. The hours counter is restarted by
switching off the control indicator.
Button
Function
Button flashes:
The filter filling must be replaced.
D
“6.2.2 Replace filter filling (with
recirculating or hybrid operation)”
(page 28).
☞
Hold the button (> 1 second) to restart the
hours counter.